    Moulded Case Circuit Breaker h1000 4P 50kA 1000A LSI HNE971H

    Add to a list
    Add to a list

    Login to create a product list

    You need to be logged into your myHager account to create product lists

    Create an account Sign in

    Moulded Case Circuit Breaker h1000 4P 50kA 1000A LSI

    HNE971H

    • Accessories
    • Technical properties
    • Environmental value
    • Documentations
    • More products
    Download the data sheet

    Complete your system

    Optional accessories

  • See more (30)
    • Handle for power circuit breaker 2 products available
    • Shunt release 6 products available
    • Under voltage coil 10 products available
    • Auxil­i­aries contact block 4 products available
    • Auxil­i­aries inter­locking cable 2 products available
    • Motor oper­ator 2 products available

    Complete your system

    • Handle for power circuit breaker
    • Shunt release
    • Under voltage coil
    • Auxil­i­aries contact block
    • Auxil­i­aries inter­locking cable
    • Motor oper­ator
    • Locking inter­locking func­tions
    • Connec­tion Func­tions
    • Terminal cover
    • HXE030H

      Direct rotary handle H800-H1000

      0.00 €  / *
    • HXE031H

      Extended rotary handle H800-H1000

      0.00 €  / *
    • HXC002H

      Shunt trip Release 48V DC (h250-h400-h630-h800-h1000)

      0.00 €  / *
    • HXC004H

      Shunt trip Release 200-240V AC (h250-h400-h630-h800-h1000)

      0.00 €  / *
    • HXC003H

      Shunt trip Release 100-120V AC (h250-h400-h630-h800-h1000)

      0.00 €  / *
    • HXC005H

      Shunt trip Release 380-450V AC (h250-h400-h630-h800-h1000)

      0.00 €  / *
    • HXC001H

      Shunt trip Release 24V DC (h250-h400-h630-h800-h1000)

      0.00 €  / *
    • HXC008H

      Shunt trip Release 110V DC (h250-h400-h630-h800-h1000)

      0.00 €  / *
    • HXE019H

      UVR 200-240 V DC (h800-h1000-h1600)

      0.00 €  / *
    • HXE018H

      UVR 100-120 V DC (h800-h1000-h1600)

      0.00 €  / *
    • HXE054H

      Undervoltage Release delayed h800-h1000 3P 220-240VAC

      0.00 €  / *
    • HXF051H

      Undervoltage Release delayed h800-h1600 4P 24VDC

      0.00 €  / *
    • HXF055H

      Undervoltage Release delayed h800-h1600 4P 380-415VAC

      0.00 €  / *
    • HXE015H

      UVR 380-415V AC (h800-h1000-h1600)

      0.00 €  / *
    • HXE013H

      UVR 110-120V AC (h800-h1000-h1600)

      0.00 €  / *
    • HXE014H

      UVR 220-240V AC (h800-h1000-h1600)

      0.00 €  / *
    • HXE011H

      UVR 24V DC (h800-h1000-h1600)

      0.00 €  / *
    • HXE051H

      Undervoltage Release delayed h800-h1600 3P 24VDC

      0.00 €  / *
    • HXC026H

      Alarm contact low level 1NO+1NC (h250-h400-h630-h800-h1000-h1600)

      0.00 €  / *
    • HXC021H

      Auxiliary contact 1NO+1NC 230V AC (h250-h400-h630-h800-h1000-h1600)

      0.00 €  / *
    • HXC025H

      Auxilirary low level 1NO+1NC 125V AC (h250-h400-h630-h800-h1000-h1600)

      0.00 €  / *
    • HXC024H

      Alarm contact 1NO+1NC 230V (h250-h400-h630-h800-h1000-h1600)

      0.00 €  / *
    • HXD068H

      Electrical interlock for Motor type A (h400-h630-x630-P630-h800-h1000)

      0.00 €  / *
    • HXB069H

      Electrical interlock for Motor type B (x250-P250-h250-h400-h630-h800-h1000)

      0.00 €  / *
    • HXE042H

      Motor operator H800-H1000 100-240VAC

      0.00 €  / *
    • HXE040H

      Motor operator h800-h1000 24-48V DC

      0.00 €  / *
    • HXE065H

      Interlocking wire type H800-H1000

      0.00 €  / *
    • HYE034H

      Rear connexion h1000 4P

      0.00 €  / *
    • HYE026H

      Terminal cover H800-H1000 4P short

      0.00 €  / *
    • HYE022H

      Terminal cover H800-H1000 4P long

      0.00 €  / *

    Technical properties

    Elec­tric current
    • Rated current
      1000 A
    • Rated ulti­mate short-­cir­cuit breaking capa­city Icu under 230 V AC IEC 60947-2
      85 kA
    • Rated ulti­mate short-­cir­cuit breaking capa­city Icu under 240 V AC IEC 60947-2
      75 kA
    • Rated ulti­mate short-­cir­cuit breaking capa­city Icu under 400 V AC IEC 60947-2
      50 kA
    • Rated ulti­mate short-­cir­cuit breaking capa­city Icu under 415 V AC IEC 60947-2
      50 kA
    • Breaking capa­city on 1-pole for AC 230 V IEC 60947-2
      45 kA
    • Breaking capa­city on 1-pole for AC 400 V IEC 60947-2
      9 kA
    Archi­tec­ture
    • Number of poles
      4
    • Control/­op­er­a­tion element
      Toggle
    • Device construc­tion type
      Fixed built-in
    Capa­city
    • Number of modules
      16
    Trip­ping
    • Response time when opening
      10 ms
    Settings
    • Magnetic protec­tion knob setting xIN
      2.5, 5, 8
    • Range of magnetic adjust­ment
      5600 A, 7000 A, 8820 A, 10000 A, 10000 A, 10000 A, 10000 A
    • Thermal protec­tion knob setting xIN
      0.4, 0.5, 0.63, 0.8, 0.9, 0.95, 1
    • Adjust­ment range short-term delayed short-­cir­cuit release
      0 - 0 A
    Frequency
    • Frequency
      50 - 60 Hz
    Install­a­tion, mounting
    • Nominal tight­ening torque
      65 - 65 Nm
    • Mount­ing-/­Con­nec­tion Posi­tion
      Front
    Voltage
    • Rated impulse with­stand voltage Uimp
      8000 V
    • Rated insu­la­tion voltage Ui
      800 V
    • Rated oper­a­tional voltage Ue
      220 - 690 V
    Func­tions
    • Trip unit
      LSI
    Main elec­trical attrib­utes
    • Magnetic protec­tion trip time
      100 - 200 ms
    Power
    • Total power loss under IN
      186 W
    • Power loss per pole at In
      62 W
    Endur­ance
    • Elec­tric endur­ance in number of cycles
      1000
    • Number of mech­an­ical oper­a­tions
      4000
    Equip­ment
    • Number of auxil­iary contacts as change-over contact
      0
    • Number of auxil­iary contacts as normally closed contact
      0
    • Number of auxil­iary contacts as normally open contact
      0
    Safety
    • Ingress Protec­tion (IP) class
      IP4X
    Use condi­tions
    • Oper­ating temper­ature
      -25 - 70 °C
    Connec­tion
    • Cross-sec­tion flex­ible conductor
      2x 240 mm²
    • Cross-sec­tion rigid conductor
      2x 240 mm²
    • Connect­or/plug type
      Terminal
    Controls and indic­ators
    • Motor drive integ­rated
      No
    Compat­ib­ility
    • Suit­able for DIN Rail
      No
    Power supply
    • Posi­tion power supply
      Bidirec­tional

    Environmental value

    We are committed to bettering our environmental performance by reducing our footprint while acting as a sustainability enabler for our customers. Learn More

    RoHS conform Yes
    REACh-SVHC free Yes

    Downloads

    • Image HNE971H  | Hager Africa

      Product Image HNE971H

    • Product datasheet

      Image Hager Product data sheet HNE971H  | Hager Africa

      Hager Product data sheet HNE971H

      Moulded Case Circuit Breaker h1000 4P 50kA 1000A LSI

      PDF
    • Declaration of conformity

      Image Declaration  | Hager Africa

      Declaration

      Declaration of conformity International 2022-06-23

      PDF
      285,31 kB
    More documentation

    Discover more of this product range

      5
    • 1
      HMW631NR - Moulded Case Circuit Breaker h3+ P630 Energy 4P4D N0-50-100% 630A 50kA FTC
      HMW631NR
      Moulded Case Circuit Breaker h3+ P630 Energy 4P4D N0-50-100% 630A 50kA FTC
    • 2
      HMW630NR - Moulded Case Circuit Breaker h3+ P630 Energy 3P3D 630A 50kA FTC
      HMW630NR
      Moulded Case Circuit Breaker h3+ P630 Energy 3P3D 630A 50kA FTC
    • 3
      HMW250NR - Moulded Case Circuit Breaker h3+ P630 Energy 3P3D 250A 50kA FTC
      HMW250NR
      Moulded Case Circuit Breaker h3+ P630 Energy 3P3D 250A 50kA FTC
    • 4
      HMT251NR - Moulded Case Circuit Breaker h3+ P250 Energy 4P4D N0-50-100% 250A 50kA FTC
      HMT251NR
      Moulded Case Circuit Breaker h3+ P250 Energy 4P4D N0-50-100% 250A 50kA FTC
    • 5
      HMT160NR - Moulded Case Circuit Breaker h3+ P250 Energy 3P3D 160A 50kA FTC
      HMT160NR
      Moulded Case Circuit Breaker h3+ P250 Energy 3P3D 160A 50kA FTC

    Products and solutions

    • Products catalog
    • Distribution systems
    • High Power & Switching
    • Modular devices
    • Electric Vehicle Charging Station (EVCS)
    • Energie management and monitoring
    • Cable routing and room connection systems
    • Wiring accessories
    • Building automation
    • Motion and presence detectors

    Contact and support

    • Find your closest wholesaler
    • Contact us
    • How to videos
    • FAQs
    • Digital tools
    • Documentation
    • Learning
    • News

    Hager Africa & Near East - Who are we

    We deliver safe and simple electrical solutions, from energy distribution and cable management, to lighting control and building automation systems for commercial and residential buildings. We want to make life on our planet safer, cleaner and more enjoyable. While being easy to work with, we remain by your side throughout the entire project, cooperating, collaborating and co-creating with you.

    More about us

    Follow us!

     title= title=
    • Cookies
    • Privacy
    • Hagergroup
    • Report a vulnerability

    Hager Group