    The Hager Earth Leakage Add-on Block 2P 63A 300mA Type A High Immunity enhances protection against earth faults while resisting nuisance tripping from harmonics and disturbances. Designed to pair with compatible breakers to create an RCD/RCBO function. Compact 2-module width, 50 Hz, Ui 500 V, Uimp 4 kV, 2000-cycle endurance, 4.4 W loss. Suitable for residential and commercial boards; secure terminals (2.8-2.9 Nm).
    EAN
    3250611362630
    VPE
    1 piece
    • Add-on blocks for MCB and multi­polar

    MCB 1P 63A Curve C 6/10kA 230-400V 1 Module BF263

    catalog.product_page.add_to_list_button
    catalog.product_page.add_to_list_button

    catalog.lists.product_addition.login_popup.title

    catalog.lists.product_addition.login_popup.descriptive_text

    catalog.lists.product_addition.login_popup.account_creation_button catalog.lists.product_addition.login_popup.login_button

    MCB 1P 63A Curve C 6/10kA 230-400V 1 Module

    BF263

    • Technical characteristics
    • catalog.pageproduct.title_sustainability.h2
    • Documentations
    • More products

    Technical characteristics

    Elec­tric current
    • Rated current IN
      63 A
    • Rated residual oper­ating current Idn
      300 mA
    Archi­tec­ture
    • Number of poles
      2
    Safety
    • Residual current type
      A HI
    Capa­city
    • Number of modules
      2
    Frequency
    • Frequency
      50 - 50 Hz
    Power
    • Power dissip­a­tion at IN
      4.4 W
    Install­a­tion, mounting
    • Nominal tight­ening torque
      2.80 - 2.80 Nm
    • Nominal tight­ening torque down terminal
      2.90 - 2.90 Nm
    Endur­ance
    • Elec­tric endur­ance in number of cycles
      2000
    Voltage
    • Rated insu­la­tion voltage Ui
      500 V
    • Rated impulse with­stand voltage Uimp
      4000 V
    • Rated oper­a­tional voltage Ue
      230 - 400 V

    catalog.pageproduct.title_sustainability.h2

    We are committed to bettering our environmental performance by reducing our footprint while acting as a sustainability enabler for our customers. Learn More

    RoHS conform Yes

    catalog.pageproduct.sustainability_block.downloads_h3

    REACH declaration BF263
    PDF
    RoHS report BF263
    PDF

    Downloads

    • Image BF263  | Hager UK

      Product Image BF263

    • GeneratedProductDatasheet

      Image Hager Product data sheet BF263  | Hager UK

      Hager Product data sheet BF263

      Earth leakage add-on block 2P 63A 300mA A high immunity Class

      PDF
    • ProductInstallationManual

      Image Installation manual en-GB, es-ES, fr-FR, it-IT, nl-NL, pt-PT 2022-04-29  | Hager UK

      Installation manual en-GB, es-ES, fr-FR, it-IT, nl-NL, pt-PT 2022-04-29

      PDF
      1,61 MB
    • ProductECDeclaration

      Image Declaration  | Hager UK

      Declaration

      Declaration of conformity International 2021-11-10

      PDF
      920,46 kB
      Image Declaration  | Hager UK

      Declaration

      Declaration of conformity International 2021-12-07

      PDF
      1,14 MB
      Image Declaration of conformity en-US 2026-07-14  | Hager UK

      Declaration of conformity en-US 2026-07-14

      PDF
      443,02 kB
      Image EU Declaration of Conformity  | Hager UK

      EU Declaration of Conformity

      Declaration of conformity en-GB 2024-11-12

      PDF
      452,70 kB
    More documentation

    Discover our other products of this range

      5
    • 1
      BFC825 - Earth leakage add-on block 4P 63A 500mA AC class 230-400V
      BFC825
      Earth leakage add-on-block with double output 4P 25A 300mA AC class
    • 2
      BDC840 - Earth leakage add-on block 4P 63A 300mA AC class, double output, 3 modules
      BDC840
      Earth leakage add-on-block with double output 4P 40A 30mA AC class
    • 3
      BDC863 - kWh meter Phase+Neutral Direct 40A Class B Optical 1 Module
      BDC863
      Earth leakage add-on-block with double output 4P 63A 30mA AC class
    • 4
      BD264 - Earth leakage add-on block 2P 63A 30mA AC Class
      BD264
      Earth leakage add-on block 2P 63A 30mA AC Class
    • 5
      BFC840 - Add-on RCCB double output 4P 25A 300mA AC 230-400V 3 modules
      BFC840
      Earth leakage add-on-block with double output 4P 40A 300mA AC class

    Products and solutions

    • Products catalog
    • Distribution systems
    • High Power & Switching
    • Modular devices
    • Electric Vehicle Charging Station (EVCS)
    • Energie management and monitoring
    • Cable routing and room connection systems
    • Wiring accessories
    • Building automation
    • Motion and presence detectors

    Contact and support

    • Find your closest wholesaler
    • Contact us
    • How to videos
    • FAQs
    • Digital tools
    • Documentation
    • Learning
    • News

    Hager Africa & Near East - Who are we

    We deliver safe and simple electrical solutions, from energy distribution and cable management, to lighting control and building automation systems for commercial and residential buildings. We want to make life on our planet safer, cleaner and more enjoyable. While being easy to work with, we remain by your side throughout the entire project, cooperating, collaborating and co-creating with you.

    More about us

    Follow us!

     title= title=
    • Cookies
    • Privacy
    • Hagergroup
    • Report a vulnerability

    Hager Group