The Hager MCB 4P C-32A 4M provides reliable overload and short-circuit protection for three-phase circuits. Rated 32A with 10kA Icn (IEC 60898-1) and Icu 15kA at 400V/30kA at 230V, it fits demanding residential, commercial and light industrial boards. 400V AC, 50/60Hz, 6kV impulse, Ui 500V. Biconnect bottom and screw terminals (1-35 mm²) speed wiring. IP20, -25…70°C, 360° mounting, compact 4 modules.
EAN
3250614616006
Packaging
3
MCB 3P 6A Curve C, 10kA Icn, 15kA Icu at 400V, 3 Modules NCN432A
Complete your system
Optional accessories
-
Modular phase busbar 1 products available -
Terminal cover 1 products available -
AOB type A-HI 2 products available -
AOB type AC 4 products available -
AOB type AC/A-SEL 1 products available
Complete your system
Technical properties
Electric current
-
Rated current32 A
-
Rated ultimate short-circuit breaking capacity Icu AC IEC 60947-215 kA
-
Rated ultimate short-circuit breaking capacity Icu under 400 V AC IEC 60947-215 kA
-
Rated current -15°C37.86 A
-
Rated current -10°C37.25 A
-
Rated current -5°C36.64 A
-
Rated current at 0°C36.01 A
-
Rated current 5°C35.37 A
-
Rated current 10°C34.73 A
-
Rated current 15°C34.06 A
-
Rated current at 20°C33.39 A
-
Rated current 25°C32.70 A
-
Rated current 30°C32 A
-
Rated current 35°C31.26 A
-
Rated current at 40°C30.50 A
-
Rated current at 45°C29.72 A
-
Rated current at 50°C28.92 A
-
Rated current 55°C28.10 A
-
Rated current 60°C27.26 A
-
Rated current 65°C26.38 A
-
Rated current 70°C25.48 A
-
Rated service breaking capacity Ics AC according to IEC 60898-17.50 kA
Architecture
-
Type of pole4P
-
CurveC
Capacity
-
Number of modules4
Main electrical attributes
-
Rated short-circuit breaking capacity Icn AC according to IEC 60898-110 kA
Installation, mounting
-
Nominal tightening torque top terminal2.80 - 2.80 Nm
-
Nominal tightening torque down terminal2.80 - 2.80 Nm
-
Nominal tightening torque2.80 - 2.80 Nm
-
Type of bottom connection for modular devicesbiconnect
-
Type of top connection for modular devicesScrew terminal
-
360° mounting position possibleYes
Voltage
-
Rated operational voltage Ue400 - 400 V
-
Type voltage supplyAC
-
Rated insulation voltage Ui500 V
-
Rated impulse withstand voltage Uimp6000 V
Frequency
-
Frequency50 - 60 Hz
Connection
-
Cross-section of input and output with screws, for massive conductors1 - 35 mm²
-
Cross-section of input and output with screws, for flexible conductors1 - 25 mm²
-
Cross-section of input with screws, for flexible conductors1 - 25 mm²
-
Cross-section of input with screws, for massive conductors1 - 35 mm²
Safety
-
Ingress Protection (IP) classIP20
-
Grid distance60 mm
Use conditions
-
Degree of pollution according to IEC 60664 / IEC 60947-22
-
Class of energy limitation I²t3
-
Operating temperature-25 - 70 °C
Power
-
Total power loss under IN16.50 W
Connectivity
-
Type of connectionScrew terminal
-
Top connection alignment for modular devicesAligned terminal
-
Down connection alignment for modular devicesAligned terminal
Dimensions
-
Height83 mm
-
Width70 mm
-
Depth70 mm
Environmental value
We are committed to bettering our environmental performance by reducing our footprint while acting as a sustainability enabler for our customers. Learn More
Certifications and documents
Downloads
More documentation