1 flush mounted output for blinds or shutters + 2 binary inputs TRB521

EAN-Nr.
3250615985200
Packaging
1 piece

This product is now obsolete. However, this page remains available for information purposes.


Technical characteristics

Architecture
  • Bus system
    KNX
  • Number of blinds/shutters outputs
    1
  • Fixing mode
    flush-mounting
Functions
  • Bus module detachable
    No
  • ETS additional functions
    ETS additional functions: +6 scenes, operating mode, 1 up/down button control, 2 x alarm, status display ; ETS additional function: repeater function
  • Quicklink functions
    quicklink functions: blind, 2 scenes, forced control, up/down push-button
Configuration
  • Number of modules
    0
Controls and indicators
  • Indicator lamp
    yes
Connectivity
  • Radio protocol
    KNX Radio
  • Receiver category
    2
Main electrical features
  • Type of supply voltage
    AC
Voltage
  • Operating voltage
    230 V AC
Electric current
  • Number of entry circuits
    2
  • Maximum switching current
    5 A
Dimensions
  • Dimensions (Ø x H)
    53 x 27 mm
Frequency
  • Radio reception frequency
    868.3 MHz
Power
  • Contact rating with 230 V in AC1
    1150 W
  • Radio transmission power
    < 10 mW
Measurement
  • Input scanning voltage
    per channel 5 V
Materials
  • Colour
    stone grey
Installation, mounting
  • Installation mode
    for installation behind flush-mounted inserts
Connection
  • Conductor cross-section
    0.5…2.5 mm²
  • Type of connection
    with screw-in lift terminals
Cable
  • Binary cable length, extendable to
    max. 5 m
  • Binary cable length
    ≈ 20 cm
Settings
  • Lamella adjustment on signal duration
    < 1 s
Scope of delivery
  • Bus connection included
    No
Equipment
  • Number of radio channels
    2
  • Number of quicklink links
    max. 20 transmitter/receiver
  • Bidirectional radio frequency
    Yes
  • Transmitter duty cycle
    1 %
  • Change-over time for change of direction
    < 0.6 s
Use
  • Pulse time
    min. 50 ms
Safety
  • Protection index IP
    IP30
Use conditions
  • Operating temperature
    0…45 °C

Downloads

More documentation