MCB 2P 25kA C-20A 2M • NRN220 | Hager
The store will not work correctly in the case when cookies are disabled.
Middle-East
  • Contact
Image Logo  | Hager
Menu
  • Products
  • Solutions
  • Support
  • Inspiration and knowledge
  • About us
Account
  • Catalogue
  • Energy distribution
  • Modular Protection devices
  • MCBs
  • MCBs NRN NQN, NSN
  • 2 pole, NRN, Curve C, 25 kA
  • NRN220
Current search
Image Filter  | Hager Filter
Image Filter  | Hager Filter
productsShow

Most popular products

5
1
NRN263 - MCB 2P 15kA C-63A 2M
NRN263
MCB 2P 15kA C-63A 2M
2
NRN232 - MCB 2P 20kA C-32A 2M
NRN232
MCB 2P 20kA C-32A 2M
3
NRN220 - MCB 2P 25kA C-20A 2M
NRN220
MCB 2P 25kA C-20A 2M
4
NRN206 - MCB 2P 25kA C-6A 2M
NRN206
MCB 2P 25kA C-6A 2M
5
NRN240 - MCB 2P 20kA C-40A 2M
NRN240
MCB 2P 20kA C-40A 2M

MCB 2P 25kA C-20A 2M

NRN220

  • MCBs

MCB 2P 25kA C-20A 2M NRN220

EAN-Nr.
3250614645020
Packaging
1 piece

You have to log in with your myHager profile to see prices and to order.

Add to a list
Add to a list

Login to create a product list

You need to be logged into your myHager account to create product lists

Create an account Sign in
  • Technical characteristics
  • Documentations
  • Accessories
  • More products
Download the sheet

Technical characteristics

Architecture
  • Neutral position
    without neutral
  • Number of protected poles
    2
  • Number of poles
    2 P
  • Type of pole
    2 P
  • Curve
    C
Functions
  • Concurrently switching N-neutral
    No
Configuration
  • Number of modules
    2
Connectivity
  • Top connection alignement for modular devices
    Aligned terminal
  • Bottom connection alignement for modular devices
    Aligned terminal
Main electrical features
  • Rated short circuit breaking capacity Icn AC according IEC60898-1
    10 kA
  • Rated operational voltage Ue
    415 V
  • Type of supply voltage
    AC
Voltage
  • Rated insulation voltage
    500 V
  • Max operating voltage
    415 V
  • Rated impulse withstand voltage
    6000 V
Electric current
  • Rated current
    20 A
  • Rated service breaking capacity Ics AC according IEC 60898-1
    7.5 kA
  • min/maxi threshold value of the AC thermal operation
    1.13 / 1.45 In
  • Magnetic regulating currrent
    5 / 10 In
  • min/maxi threshold value of the DC magnetic operation
    5 / 15 In
  • min/maxi threshold value of the DC thermal operation
    1.13 / 1.45 In
  • Rating current -10°C according to IEC 60947
    26.75 A
  • Rating current -15°C according to IEC 60947
    27.24 A
  • Rating current -20°C according to IEC 60947
    27.72 A
  • Rating current -25°C according to IEC 60947
    28.19 A
  • Rating current -5°C according to IEC 60947
    26.26 A
  • Rating current 0°C according to IEC 60947
    25.75 A
  • Rating current 10°C according to IEC 60947
    24.71 A
  • Rating current 15°C according to IEC 60947
    24.17 A
  • Rating current 20°C according to IEC 60947
    23.62 A
  • Rating current 25°C according to IEC 60947
    23.06 A
  • Rating current 30°C according to IEC 60947
    22.48 A
  • Rating current 35°C according to IEC 60947
    21.88 A
  • Rating current 40°C according to IEC 60947
    21.28 A
  • Rating current 45°C according to IEC 60947
    20.65 A
  • Rating current 5°C according to IEC 60947
    25.24 A
  • Rating current 50°C according to IEC 60947
    20 A
  • Rating current 55°C according to IEC 60947
    19.33 A
  • Rating current 60°C according to IEC 60947
    18.64 A
  • Rating current 65°C according to IEC 60947
    17.92 A
  • Rating current 70°C according to IEC 60947
    17.17 A
  • Breaking capacity on 1 pole for IT 400V NF 60947-2
    3 kA
  • Rated short circuit breaking capacity Icn under 230V AC according IEC60898-1
    10 kA
  • Rated short circuit breaking capacity Icn under 400V AC according IEC60898-1
    10 kA
  • Rated ultimate short-circuit breaking capacity Icu under 230V AC IEC 60947-2
    50 kA
  • Rated ultimate short-circuit breaking capacity Icu under 240V AC IEC 60947-2
    50 kA
  • Rated ultimate short-circuit breaking capacity Icu under 400V AC IEC 60947-2
    25 kA
  • Rated ultimate short-circuit breaking capacity Icu under 415V AC IEC 60947-2
    25 kA
  • Rated short circuit breaking capacity Icn under 240V AC according IEC 60898-1
    10 kA
  • Rated short circuit breaking capacity Icn under 415V AC according IEC 60898-1
    10 kA
  • Rated ultimate short-circuit breaking capacity Icu under 220V AC IEC 60947-2
    50 kA
  • Rated ultimate short-circuit breaking capacity Icu under 380V AC IEC 60947-2
    25 kA
Current correction factors
  • Correction factor of rating current for 2 devices placed side-by-side
    1
  • Correction factor of rating current for 3 devices placed side-by-side
    0.95
  • Correction factor of rating current for 4 and 5 devices placed side-by-side
    0.9
  • Correction factor of rating current for 6 devices placed side-by-side
    0.85
  • Correction factor of magnetic tripping with 100 Hz
    1.1
  • Correction factor of magnetic tripping with 200 Hz
    1.2
  • Correction factor of magnetic tripping with 400 Hz
    1.5
  • Correction factor of magnetic tripping with 60 Hz
    1
Dimensions
  • Depth of installed product
    70 mm
  • Height of installed product
    83 mm
  • Width of installed product
    35 mm
Frequency
  • Frequency
    50 to 60 Hz
Power
  • Maximum power loss per pole according to the product standard
    4.5 W
  • Total power loss under IN
    5.29 W
  • Power loss per pole at In
    2.68 W
Tripping
  • Time of response when opening
    7 ms
Endurance
  • Electric endurance in number of cycles
    4000
  • Number of mechanical operations
    20000
Installation, mounting
  • Type of top connection for modular devices
    with screw
  • Tightening torque
    2,8Nm
  • Type of top rail clip for modular devices
    NA
  • Type of bottom rail clip for modular devices
    plastic
  • Type of Bottom Connection for modular devices
    BIconnect
  • Top removability for modular devices
    Yes
  • Bottom removability for modular devices
    Yes
  • Suitable for flush-mounting
    Yes
Connection
  • Connection cross-section at output with screw, for flexible conductor
    1 / 25 mm²
  • Connection cross-section at output with screw, for massive conductor
    1 / 35 mm²
  • Connection cross-section for rigid conductor, upstream terminals with screws
    1 / 35 mm²
  • Connection cross-section of the access with screws, with flexible conductor
    1 / 25 mm²
  • Downstream cage clamp delivery status
    opened
  • Upstream cage clamp delivery status
    opened
Equipment
  • Can be accessorized
    Yes
Standards
  • Standard text
    IEC 60947-2
Safety
  • REACH conform
    No
  • RoHS conform
    Yes
  • Halogen free
    No
Use conditions
  • Operating temperature
    -25…70 °C
  • Degree of pollution according to IEC 60664 / IEC 60947-2
    2
  • Class of energy limitation I²t
    3
  • Altitude
    2000 m
  • Air humidity protection
    for all climates
  • Storage/transport temperature
    -25…80 °C
temperatur
  • Temperature of calibration
    50 °C

Downloads

  • Product image

    Image NRN220  | Hager

    Product Image NRN220

  • Declaration of conformity

    Image EU Declaration of conformity for NRN220  | Hager

    EU Declaration of conformity for NRN220

    UKCA Declaration of Conformity

    PDF
    653 KB
    Image EU Declaration of conformity for NRN220  | Hager

    EU Declaration of conformity for NRN220

    Declaration

    PDF
    710 KB
    Image EU Declaration of conformity for NRN220  | Hager

    EU Declaration of conformity for NRN220

    Declaration

    PDF
    689 KB
    Image EU Declaration of conformity for NRN220  | Hager

    EU Declaration of conformity for NRN220

    EU Declaration of Conformity

    PDF
    650 KB
  • PEP document

    Image Product environmental profile for NRN220  | Hager

    Product environmental profile for NRN220

    PDF
    432 KB
  • RoHS report

    Image Pollutant guidelines for NRN220  | Hager

    Pollutant guidelines for NRN220

    RoHS declaration NRN220 (english)

    PDF
    103 KB
More documentation

Optional accessories

See more

Discover our other products of this range

    5
  • 1
    NRN206 - MCB 2P 25kA C-6A 2M
    NRN206
    MCB 2P 25kA C-6A 2M
  • 2
    NRN210 - MCB 2P 25kA C-10A 2M
    NRN210
    MCB 2P 25kA C-10A 2M
  • 3
    NRN216 - MCB 2P 25kA C-16A 2M
    NRN216
    MCB 2P 25kA C-16A 2M
  • 4
    NRN225 - MCB 2P 25kA C-25A 2M
    NRN225
    MCB 2P 25kA C-25A 2M
  • 5
    NRN232 - MCB 2P 20kA C-32A 2M
    NRN232
    MCB 2P 20kA C-32A 2M

Contact and support

  • Contact us
  • Newsletter
  • Training
  • FAQs
  • Webinars
  • How-to videos
  • Digital tools

Products and solutions

  • Product catalog
  • Energy distribution
  • Cable management 
  • Wiring accessories and building automation
  • Security
  • Project references

Who are we?

Your reli­able partner for inte­l­li­gent solut­ions. Hager Middle East is your provider of solut­ions and services for elect­rical instal­lat­ions in resid­e­ntial and comme­rcial segments. Based in Dubai (United Arab Emirates), we have regi­onal offices in Kingdom of Saudi Arabia and Qatar, alon­gside repre­s­e­ntative in Oman. Since 1997, we work on better products and inno­vative techn­o­logies making your work easier and deliver strong techn­ical support and expe­rtise in the region.

Hager Middle East is a member of Hager Group, a family business  based in Blie­s­kastel, Germany since 1955. World­wide, Hager group gene­rates a turn­over of 2 billion euros, and more than 6% is rein­vested in rese­arch and deve­l­o­pment. 

More about us & Working with us: Follow us on LinkedIn

Follow us !

  • Cookies
  • Privacy
  • Hagergroup
  • Report a vulnerability

©Ha­ger Group