Moulded Case Circuit Breaker x160 3P 40kA 25A

HNA025Z

  • h3 MCCBs

Moulded Case Circuit Breaker x160 3P 40kA 25A HNA025Z

EAN-Nr.
3250613149574
Packaging
1 piece

You have to log in with your myHager profile to see prices and to order.

Add to a list
Add to a list

Login to create a product list

You need to be logged into your myHager account to create product lists

Create an account Sign in
  • Technical characteristics
  • Documentations
  • Accessories
  • More products
Download the sheet

Technical characteristics

Architecture
  • Type of order
    Toggle
  • Number of poles
    3 P
  • Type of pole
    3P3D
Functions
  • Complete device with protection unit
    Yes
  • Trip Unit
    TM F/F
  • With integrated earth leakage fault protection
    No
Configuration
  • Number of modules
    4.5
Main electrical features
  • Rated operational voltage Ue
    220 / 415 V
  • Frequency
    50/60 Hz
Voltage
  • Rated insulation voltage
    690 V
  • Rated impulse withstand voltage
    8 kV
  • With under voltage release
    No
Electric current
  • Rated current
    25 A
  • Rated ultimate short-circuit breaking capacity Icu under 690V AC IEC 60947-2
    6 kA
  • Thermal protection nob setting xIN
    1
  • Breaking capacity on 1 pole for IT 230V NF 60947-2
    51 kA
  • Breaking capacity on 1 pole for IT 400V NF 60947-2
    9 kA
  • Rated service breaking capacity Ics AC according IEC 60947-2
    50 %
  • Rated ultimate short-circuit breaking capacity Icu under 230V AC IEC 60947-2
    85 kA
  • Rated ultimate short-circuit breaking capacity Icu under 240V AC IEC 60947-2
    85 kA
  • Rated ultimate short-circuit breaking capacity Icu under 400V AC IEC 60947-2
    40 kA
  • Rated ultimate short-circuit breaking capacity Icu under 415V AC IEC 60947-2
    40 kA
  • Rated ultimate short-circuit breaking capacity Icu under 440V AC IEC 60947-2
    25 kA
Current correction factors
  • Correction factor of rating current for 2 devices placed side-by-side
    1
  • Correction factor of rating current for 3 devices placed side-by-side
    1
  • Correction factor of rating current for 4 and 5 devices placed side-by-side
    1
  • Correction factor of rating current for 6 devices placed side-by-side
    1
Power
  • Total power loss under IN
    13.7 W
  • Power loss per pole at In
    4.6 W
Tripping
  • Tripmode
    TM
  • Thermal protection trip time
    0 ms
  • Time of response when opening
    10 ms
Electrical specifications
  • Magnetic trip delay time
    0 ms
Endurance
  • Electric endurance in number of cycles
    1000
  • Number of mechanical operations
    4000
Installation, mounting
  • DIN rail mounting with optional adaptator
    Yes
Connection
  • Connection cross-sect. flexible conductor
    4 / 70mm²
  • Connection cross-sect. rigid cable
    4 / 95mm²
  • Connection
    Front connection
  • Type of connection
    with screw
Settings
  • Range of the magnetic adjustment
    600 A
  • Setting type In or Ith
    IN
Equipment
  • Number of auxiliary contacts as normally closed contact
    0
  • Number of auxiliary contacts as normally open contact
    0
  • Number of auxiliary contacts as change-over contact
    0
  • Motor drive optional
    No
Use cases
  • Category of use
    A
Standards
  • Standard text
    IEC 60947-2
  • European directive WEEE
    concerned
Use conditions
  • Operating temperature
    -25…70 °C
  • Altitude
    2000 m
  • Air humidity protection
    for all climates
  • Storage/transport temperature
    -35…70 °C

Downloads

  • Product image

    Image HNA025Z  | Hager

    Product Image HNA025Z

  • Instruction manual

    Image Instruction manuals for HNA025Z  | Hager

    Instruction manuals for HNA025Z

    PDF
    12 MB
  • Declaration of conformity

    Image EU Declaration of conformity for HNA025Z  | Hager

    EU Declaration of conformity for HNA025Z

    Declaration

    PDF
    276 KB
    Image EU Declaration of conformity for HNA025Z  | Hager

    EU Declaration of conformity for HNA025Z

    Declaration

    PDF
    215 KB
    Image EU Declaration of conformity for HNA025Z  | Hager

    EU Declaration of conformity for HNA025Z

    UKCA Declaration of Conformity

    PDF
    435 KB
    Image EU Declaration of conformity for HNA025Z  | Hager

    EU Declaration of conformity for HNA025Z

    EU Declaration of Conformity

    PDF
    430 KB
More documentation

Optional accessories

See more

Discover our other products of this range

    5
  • 1
    HNA016Z - Moulded Case Circuit Breaker x160 3P 40kA 16A
    HNA016Z
    Moulded Case Circuit Breaker x160 3P 40kA 16A
  • 2
    HNA020Z - Moulded Case Circuit Breaker h3 x160 TM FIX 3P3D  20A 40kA CTC
    HNA020Z
    Moulded Case Circuit Breaker h3 x160 TM FIX 3P3D 20A 40kA CTC
  • 3
    HNA032Z - Moulded Case Circuit Breaker h3 x160 TM FIX 3P3D  32A 40kA CTC
    HNA032Z
    Moulded Case Circuit Breaker h3 x160 TM FIX 3P3D 32A 40kA CTC
  • 4
    HNA040Z - Moulded Case Circuit Breaker h3 x160 TM FIX 3P3D  40A 40kA CTC
    HNA040Z
    Moulded Case Circuit Breaker h3 x160 TM FIX 3P3D 40A 40kA CTC
  • 5
    HNA050Z - Moulded Case Circuit Breaker h3 x160 TM FIX 3P3D  50A 40kA CTC
    HNA050Z
    Moulded Case Circuit Breaker h3 x160 TM FIX 3P3D 50A 40kA CTC

Contact and support

  • Contact us
  • Newsletter
  • Training
  • FAQs
  • Webinars
  • How-to videos
  • Digital tools

Products and solutions

  • Product catalog
  • Energy distribution
  • Cable management 
  • Wiring accessories and building automation
  • Security
  • Project references

Who are we?

Your reli­able partner for inte­l­li­gent solut­ions. Hager Middle East is your provider of solut­ions and services for elect­rical instal­lat­ions in resid­e­ntial and comme­rcial segments. Based in Dubai (United Arab Emirates), we have regi­onal offices in Kingdom of Saudi Arabia and Qatar, alon­gside repre­s­e­ntative in Oman. Since 1997, we work on better products and inno­vative techn­o­logies making your work easier and deliver strong techn­ical support and expe­rtise in the region.

Hager Middle East is a member of Hager Group, a family business  based in Blie­s­kastel, Germany since 1955. World­wide, Hager group gene­rates a turn­over of 2 billion euros, and more than 6% is rein­vested in rese­arch and deve­l­o­pment. 

More about us & Working with us: Follow us on LinkedIn

Follow us !

  • Cookies
  • Privacy
  • Hagergroup
  • Report a vulnerability

©Ha­ger Group