Moulded Case Circuit Breaker h3+ P630 LSI 4P4D N0-50-100% 400A 50kA FTC HMW401JR
Login to create a product list
You need to be logged into your myHager account to create product lists
Technical characteristics
-
Type of orderToggle
-
Neutral positionleft
-
Number of protected poles4
-
Number of poles4 P
-
Type of pole4P4D N:0/50/100%
-
Type of caseFixed built-in
-
Complete device with protection unitYes
-
Version as main switchYes
-
Version as emergency stop installationNo
-
Version as safety switchNo
-
Version as maintenance-/service switchYes
-
Trip UnitLSI
-
Integrated earth fault protectionNo
-
Concurrently switching N-neutralYes
-
Motor drive integratedNo
-
Rated operational voltage Ue220 / 690 V
-
Type of supply voltageAC
-
Frequency50/60 Hz
-
Rated insulation voltage800 V
-
Rated impulse withstand voltage8 kV
-
With under voltage releaseNo
-
Rated current400 A
-
Rated ultimate short-circuit breaking capacity Icu under 690V AC IEC 60947-212 kA
-
Rating current 10°C according to IEC 60947400 A
-
Rating current 15°C according to IEC 60947400 A
-
Rating current 20°C according to IEC 60947400 A
-
Rating current 25°C according to IEC 60947400 A
-
Rating current 30°C according to IEC 60947400 A
-
Rating current 35°C according to IEC 60947400 A
-
Rating current 40°C according to IEC 60947400 A
-
Rating current 45°C according to IEC 60947400 A
-
Rating current 50°C according to IEC 60947400 A
-
Rating current 55°C according to IEC 60947400 A
-
Rating current 60°C according to IEC 60947400 A
-
Rating current 65°C according to IEC 60947400 A
-
Rating current 70°C according to IEC 60947400 A
-
Rated service breaking capacity Ics under 660V AC according IEC 60947-212 kA
-
Breaking capacity on 1 pole for IT 230V NF 60947-210 kA
-
Breaking capacity on 1 pole for IT 400V NF 60947-210 kA
-
Breaking capacity on 1 pole for IT 415V NF 60947-210 kA
-
Rated ultimate short-circuit breaking capacity Icu under 230V AC IEC 60947-285 kA
-
Rated ultimate short-circuit breaking capacity Icu under 240V AC IEC 60947-285 kA
-
Rated ultimate short-circuit breaking capacity Icu under 400V AC IEC 60947-250 kA
-
Rated ultimate short-circuit breaking capacity Icu under 415V AC IEC 60947-250 kA
-
Rated ultimate short-circuit breaking capacity Icu under 220V AC IEC 60947-285 kA
-
Rated ultimate short-circuit breaking capacity Icu under 380V AC IEC 60947-250 kA
-
Rated ultimate short-circuit breaking capacity Icu under 660V AC IEC 60947-212 kA
-
Depth of installed product150 mm
-
Height of installed product260 mm
-
Width of installed product185 mm
-
Frequency50 to 60 Hz
-
Power loss per pole at 0.63*In12 W
-
Power loss per pole at 0.8*In19.2 W
-
Total power loss at 0.63*In36 W
-
Total power loss at 0.8*In57.6 W
-
Total power loss under IN90 W
-
Power loss per pole at In30 W
-
Time of response when opening10 ms
-
Tightening torque18Nm
-
DIN rail mounting with optional adaptatorNo
-
Suitable for front mountingNo
-
Suitable for ground mountingYes
-
ConnectionFront connection
-
Type of connectionTerminal
-
Cable MaterialCu
-
Number of auxiliary contacts as normally closed contact0
-
Number of auxiliary contacts as normally open contact0
-
Number of auxiliary contacts as change-over contact0
-
Motor drive optionalYes
-
Can be accessorizedYes
-
Category of useB
-
Standard textIEC 60947-2
-
REACH conformNo
-
RoHS conformYes
-
Halogen freeNo
-
Degree of pollution according to IEC 60664 / IEC 60947-23
-
Altitude2000 m
-
Temperature of calibration50 °C
Downloads
-
Product image
-
Instruction manual
Instruction manuals for HMW401JR
Manual for moulded case circuit breaker h3+ P630 (Date: 2020-03)
PDF5 MBInstruction manuals for HMW401JR
Manual for moulded case circuit breaker h3+ P630 (Date: 2023-02)
PDF10 MBInstruction manuals for HMW401JR
PDF1 MB -
Operating manual
Utilization manuals for HMW401JR
Operating manual International 2020-09-21
PDF13 MB -
Installation handbook
Installation handbooks for HMW401JR
PDF48 MB -
STEP files
STEP models for HMW401JR
CAD file for MCCB 630A 4P
STP1023 KB -
Declaration of conformity
EU Declaration of conformity for HMW401JR
PDF343 KBEU Declaration of conformity for HMW401JR
EU declaration of conformity
PDF569 KBEU Declaration of conformity for HMW401JR
Declaration
PDF355 KBEU Declaration of conformity for HMW401JR
MCCB P630
PDF587 KBEU Declaration of conformity for HMW401JR
Declaration
PDF374 KBEU Declaration of conformity for HMW401JR
Declaration
PDF332 KBEU Declaration of conformity for HMW401JR
EU Declaration of Conformity
PDF588 KB -
PEP document
Product environmental profile for HMW401JR
PDF435 KB -
RoHS report
Pollutant guidelines for HMW401JR
REACH-declaration 2023-10-20 (english)
PDF33 KBPollutant guidelines for HMW401JR
RoHS-declaration 2023-10-20 (english)
PDF33 KB