    • SPV340
    EAN
    3250615514967
    Packaging
    1 Piece
    • Surge Protec­tion Device (SPD)

    SPD T2 2P pluggable 40kA photovoltaic SPV340

    Add to a list
    Add to a list

    Login to create a product list

    You need to be logged into your myHager account to create product lists

    Create an account Sign in

    SPD T2 2P pluggable 40kA photovoltaic

    SPV340

    • Accessories
    • Technical properties
    • Environmental value
    • Documentations
    • More products
    Download the data sheet

    Complete your system

    Optional accessories

    • Accessor­ies/s­pare parts for surge protec­tion power supply systems 1 products available

    Complete your system

    • Accessor­ies/s­pare parts for surge protec­tion power supply systems
    • SPV040

      Cartridge T2 1P photovoltaic +/- for SPV340

      €0.00  / *

    Technical properties

    Capa­city
    • Number of modules
      3
    Voltage
    • Voltage protec­tion level Up according to IEC 61643-1
      3.70 kV
    • Mode of protec­tion design
      Voltage-lim­iting type
    • Voltage level Up L-N/PEN IEC 61643-11
      3,700 V
    • Type voltage supply
      DC
    • Overvoltage category according to IEC 60947-1
      3
    Elec­tric current
    • Max. discharge current (Imax)
      40 kA
    • Max. discharge current (Imax) N-PE
      40 kA
    • Nominal discharge current In
      15 kA
    Dimen­sions
    • Height
      89.80 mm
    • Width
      53.40 mm
    • Depth
      56.1 mm
    • Strip­ping length
      16 mm
    Safety
    • Ingress Protec­tion (IP) class
      IP20
    • Mode of protec­tion
      L-PE
    Use condi­tions
    • Oper­ating temper­ature
      -40 - 80 °C
    • Air humidity protec­tion
      5 - 95%
    • Stor­age/trans­port temper­ature
      -40 - 80 °C
    • Degree of pollu­tion according to IEC 60664 / IEC 60947-2
      2
    • Max. alti­tude
      2,000 m
    Mater­ials
    • Product colour
      Light grey
    • RAL code
      7035
    • Material
      Poly­amide (PA), Poly­ester
    Network config­ur­a­tion
    • Network type
      DC
    • Network TN
      No
    • Network TN-C
      No
    • Network DC
      Yes
    • Network IT
      No
    • Network TT
      No
    • Network TN-C-S
      Yes
    • Network TN-S
      No
    Equip­ment
    • With remote signalling contact
      No
    • Nominal load current IL
      80 A
    Connec­tion
    • Cross-sec­tion of input and output with screws, for flex­ible conductors
      1.5 - 25 mm²
    • Cross-sec­tion of input and output with screws, for massive conductors
      1.5 - 35 mm²
    • Cross-sec­tion flex­ible conductor
      1.5 - 25 mm²
    • Cross-sec­tion rigid conductor
      1.5 - 35 mm²
    • Connect­or/plug type
      Screw terminal
    • Number of connec­tions
      1
    Stand­ards
    • Require­ment class IEC 61643
      T2
    Frequency
    • Frequency
      50 - 60 Hz
    Install­a­tion, mounting
    • Nominal tight­ening torque
      3 - 4.5 Nm
    • Mount­ing-/­Con­nec­tion Posi­tion
      Hori­zontal
    • Suit­able for indoor usage
      Yes
    Archi­tec­ture
    • Type of pole
      2P
    Config­ur­a­tion
    • With integ­rated protec­tion fuse
      No
    Connectivity
    • Mounting type
      DIN rail
    • Type of connec­tion
      Screw connec­tion
    Controls and indic­ators
    • With indic­ator lamp
      Yes
    Func­tions
    • Discon­nector indic­a­tion
      Optical
    • Suit­able for addi­tional system config­ur­a­tion
      Yes
    • End of life mode
      OCM (open circuit mode)
    Internal use only
    • Number of half modules of 17,5 mm
      6
    Specific iden­ti­ficaton attrib­utes for Protec­tion
    • Filter Type product
      SPD

    Environmental value

    We are committed to bettering our environmental performance by reducing our footprint while acting as a sustainability enabler for our customers Learn More

    RoHS conform Yes
    REACh-SVHC free Yes

    Certifications and documents

    REACH declaration SPV340
    PDF
    RoHS report SPV340
    PDF

    Downloads

    • Product image

      Image SPV340  | Hager

      Product Image SPV340

    • Product datasheet

      Image Hager Product data sheet SPV340  | Hager

      Hager Product data sheet SPV340

      SPD T2 2P pluggable 40kA photovoltaic

      PDF
    • Declaration of conformity

      Image Declaration of conformity en-US 2026-07-15  | Hager

      Declaration of conformity en-US 2026-07-15

      PDF
      346,66 kB
    More documentation

    Discover more of this product range

      5
    • 1
      JN201SPD - 250A Panelboard Surge Protection Kit Type I
      JN201SPD
      250A Panelboard Surge Protection Kit Type I
    • 2
      SPB008D - Cartridge L-N Uc 275 In 2kA Imax 8kA Up 1kV
      SPB008D
      Cartridge L-N Uc 275 In 2kA Imax 8kA Up 1kV
    • 3
      JK101SPD - 125A Surge Protection Kit Type I/II
      JK101SPD
      125A Surge Protection Kit Type I/II
    • 4
      JK201SPD - 250A Surge Protection Kit Type I
      JK201SPD
      250A Surge Protection Kit Type I
    • 5
      SPB015 - Cartridge T2 L-N Uc 275V Imax 40kA Up 1.35kV
      SPB015
      Cartridge T2 L-N Uc 275V Imax 40kA Up 1.35kV

    Products

    • Commercial Distribution
    • Modular Devices and Connection
    • Lighting Connection and Control
    • Residential Distribution
    • Wiring Accessories
    • References

    Solutions

    • Single house
    • Multi-residential
    • Office
    • Hotel
    • Other

    Support

    • FAQs
    • Contact us
    • Catalogues
    • Download center
    • Training
    • How-to videos

    Who we are

    We deliver safe and simple electrical solutions, from energy distribution to lighting control and wiring accessories systems for commercial and residential buildings. We want to make life on our planet safer, cleaner and more enjoyable. While being easy to work with, we remain by your side throughout the entire project, cooperating, collaborating and co-creating with you.

     

    More about us

    Fol­low us

      • Privacy
      • Cookies
      • Report a vulnerability
      • Hagergroup

    Hager Ltd, Unit M2 Furry Park Industrial Estate, Santry, Dublin D09 NY19, Ireland