  • TYA606E

Output 6 -fold 16A C-Load adapted with current monitoring

TYA606E

  • Wiring accessories and Building auto­ma­tion

Output 6 -fold 16A C-Load adapted with current monitoring TYA606E

EAN
3250616059917
Packaging
1 Piece

You have to log in with your myHager profile to see prices and to order.

Add to a list
Add to a list

Login to create a product list

You need to be logged into your myHager account to create product lists

Create an account Sign in
  • Technical properties
  • Documentations
  • More products
Download the data sheet

Technical properties

Archi­tec­ture
  • Bus system
    KNX
Func­tions
  • Multi-phase mode
    suit­able to switch different external conductors
  • Func­tion
    with oper­ating hours meter
  • Switching
    for switch­ing, e.g. of 6 inde­pendent loads
Config­ur­a­tion
  • Number of modules
    6
Controls and indic­ators
  • Indic­ator lamp
    yes
  • Oper­a­tion
    manual oper­a­tion can be activ­ated via 2-level selec­tion switch, thereby deac­tiv­a­tion of the KNX func­tion
  • Indic­a­tion / display
    status LED integ­rated in the manual oper­a­tion button
  • Button / push-button
    with illu­min­ated program­ming button
Main elec­trical features
  • Rated oper­a­tional voltage Ue
    230 V
  • Frequency
    50/60 Hz
  • Rated current
    16 A
Voltage
  • Max. switching capa­city at
    230 V AC
  • Oper­ating voltage over bus
    21…32 V DC
  • Output voltage
    230 V~
  • System supply voltage
    30V DC via bus
Elec­tric current
  • Bus current consump­tion (data trans­fer)
    6 mA
  • Bus current consump­tion (idle)
    5 mA
  • Number of entry circuits
    0
  • Maximum through current
    16 A
  • Rated current
    16 A
  • Switching current at cos φ = 0.8
    max. 16 A
Dimen­sions
  • Width of rail mounted device (RMD)
    6 modules
Power
  • Max. power with elec­tronic transfo.
    1380 W
  • Total power loss under IN
    6 W
  • Output power
    2300 W
  • Max. switching power
    9775 W
  • Conven­tional trans­formers
    1600 VA
  • Elec­tronic trans­formers
    1380 W
Lighting control
  • Fluor­es­cent lamps with elec­tron­ical ballast (EB)
    25 x 18 W
  • - uncom­pensated
    800 W
Fluor­es­cent bulbs control
  • Energy-saving lamps
    25 x 18 W
  • Power lighting fluo lamps
    25x18W
  • Max. power fluo. duo lamp comp. series
    25x18W
LED control
  • 230 V retrofit LED lamps
    200 W
  • Power LED
    216 W
  • LED
    Status LED integ­rated in manual oper­a­tion button
Incan­des­cent bulbs control
  • Max. power with incan­des­cent lamps
    2300 W
  • 230 V incan­des­cent lamps
    2300 W
  • 230 V halogen lamps
    2300 W
  • 230 V incan­des­cent lamps and halogen lamps
    2300 W
Connec­tion
  • Connec­tion cross-sect. flex­ible conductor
    0,75 / 2,5mm²
  • Connec­tion cross-sect. rigid cable
    0,75 / 2.5mm²
  • Type of load
    C-Load
  • Conductor cross-sec­tion (flex­ible)
    0.75…2.5 mm²
  • Conductor cross-sec­tion (rigid)
    0.75…2.5 mm²
  • Type of contacts
    6NO
  • Bus coup­ling unit
    with integral bus coup­ling unit
  • Type of connec­tion
    with plug-in terminals
  • Bus connec­tion
    bus connec­tion via connecting terminal
  • Type of connec­tion
    quick connect
Settings
  • Supported config­ur­a­tion modes
    system
Scope of delivery
  • Bus connec­tion included
    Yes
Equip­ment
  • Modular expand­ab­ility
    No
Use
  • Differ­en­ti­ation char­ac­ter­istic 3 - Sales
    with plug-in terminals
Safety
  • REACH conform
    No
  • RoHS conform
    Yes
  • Halogen free
    No
Use condi­tions
  • Oper­ating temper­ature
    -5…45 °C
  • Stor­age/trans­port temper­ature
    -20…70 °C
Iden­ti­fic­a­tion
  • Main design line
    KNX

Downloads

  • Product image

    Image TYA606E  | Hager Africa

    Product Image TYA606E

  • ProductNotice

    Image Instruction manuals for TYA606E  | Hager Africa

    Instruction manuals for TYA606E

    PDF
    1 MB
  • ProductETSBase

    Image Product-Database ETS for TYA606E  | Hager Africa

    Product-Database ETS for TYA606E

    Logiciel d'application ETS du TYB606E

    VD5
    641 KB
    Image Product-Database ETS for TYA606E  | Hager Africa

    Product-Database ETS for TYA606E

    Logiciel d'application ETS du TYB606E

    KNXPROD
    448 KB
  • ProductApplicationDescription

    Image Application guides ETS / easy link for TYA606E  | Hager Africa

    Application guides ETS / easy link for TYA606E

    Description d'application ETS TYA606E EN

    PDF
    4 MB
  • ProductECDeclaration

    Image EU Declaration of conformity for TYA606E  | Hager Africa

    EU Declaration of conformity for TYA606E

    Declaration

    PDF
    137 KB
  • ProductROHS

    Image Pollutant guidelines for TYA606E  | Hager Africa

    Pollutant guidelines for TYA606E

    RoHS declaration TYA606E (english)

    PDF
    33 KB
    Image Pollutant guidelines for TYA606E  | Hager Africa

    Pollutant guidelines for TYA606E

    REACH declaration TYA606E (english)

    PDF
    33 KB
  • ProductEnvironmentProfile

    Image Product environmental profile for TYA606E  | Hager Africa

    Product environmental profile for TYA606E

    PDF
    321 KB
More documentation

Discover more of this product range

    4
  • 1
    TXA206A - Output 6 -fold 4A
    TXA206A
    Output 6 -fold 4A
  • 2
    TXA206B - Output 6 -fold 10A
    TXA206B
    Output 6 -fold 10A
  • 3
    TXA206C - Output 6 -fold 16A
    TXA206C
    Output 6 -fold 16A
  • 4
    TXA206D - Output 6 -fold 16A C-Load adapted
    TXA206D
    Output 6 -fold 16A C-Load adapted

Products and solutions

  • Products catalog
  • Energy distribution
  • Energy management
  • Cable management
  • Building automation
  • Wiring accessories
  • Security
  • Reference projects

Contact and support

  • Find your closest wholesaler
  • Contact us
  • How to videos
  • FAQs
    Digital tools
  • Documentation
  • Learning
  • News

Hager Africa & Near East - Who are we

We deliver safe and simple elect­rical solut­ions, from energy distrib­ution and cable manag­ement, to lighting control and building autom­ation systems for comme­rcial and resid­e­ntial buildings. We want to make life on our planet safer, cleaner and more enjo­yable. While being easy to work with, we remain by your side thro­ug­hout the entire project, coope­rating, collabo­rating and co-creating with you.

More about us

Follow us!

  • Cookies
  • Privacy
  • Hagergroup
  • Report a vulnerability

© 2022 Ha­ger Group