  • TXB692F

Output module 2x 6A /230V~, 2 inputs, flush mounted, KNX

TXB692F

  • Wiring accessories and Building auto­ma­tion

Output module 2x 6A /230V~, 2 inputs, flush mounted, KNX TXB692F

EAN
3250616048881
Packaging
1 Piece

You have to log in with your myHager profile to see prices and to order.

Add to a list
Add to a list

Login to create a product list

You need to be logged into your myHager account to create product lists

Create an account Sign in
  • Technical properties
  • Documentations
  • Accessories
  • More products
Download the data sheet

Technical properties

Archi­tec­ture
  • Number of blind­s/shut­ters outputs
    1
Func­tions
  • Multi-phase mode
    for 1 phase oper­a­tion
  • Func­tion
    with posi­tioning func­tion for blind and lamella posi­tion ; with safety func­tions e.g. for wind, rain, alarm ; binary input func­tions: Switch­ing, dimming, blind, value trans­mit­ter, scene, prior­ity, timer oper­a­tion, subplate
  • Switching
    for switching e.g. 2 inde­pendent loads or activ­a­tion of a drive
Config­ur­a­tion
  • Number of modules
    0
Controls and indic­ators
  • Indic­ator lamp
    yes
  • Oper­a­tion
    test mode/building site mode can be activ­ated via program­ming button ; manual oper­a­tion in test mode via program­ming button (single-area oper­a­tion)
  • Control
    for activ­a­tion of a drive for altern­ating current
  • Button / push-button
    with illu­min­ated program­ming button
Connectivity
  • Binary inputs
    with 2 inde­pendent binary inputs for poten­tial-­free contacts
Main elec­trical features
  • Rated oper­a­tional voltage Ue
    230 V
  • Type of supply voltage
    DC
  • Rated current
    6 A
Voltage
  • Max. switching capa­city at
    230 V AC
  • Oper­ating voltage over bus
    21…32 V DC
  • Output voltage
    230 V AC
  • System supply voltage
    30V DC via bus
Elec­tric current
  • Bus current consump­tion (data trans­fer)
    7 mA
  • Bus current consump­tion (idle)
    5 mA
  • Number of entry circuits
    2
  • Maximum switching current
    6 A
  • Maximum through current
    6 A
  • Rated current
    6 A
  • Switching current at cos φ = 0.8
    max. 6 A
  • With­stand current in AC1 for the contact path or zone 1
    6 A
Dimen­sions
  • Height of installed product
    44 mm
  • Dimen­sions (LLx­wwxhh)
    44 x 43 x 22 mm
  • Width of rail mounted device (RMD)
    0 modules
  • Height
    44 mm
Power
  • Max. power with elec­tronic transfo.
    500 W
  • Contact rating with 230 V in AC1
    1380 W
  • Total power loss under IN
    0.5 W
  • Output power
    500 W
  • Conven­tional trans­formers
    500 VA
  • Elec­tronic trans­formers
    500 W
Meas­ure­ment
  • Input scan­ning voltage
    12 V DC V DC
Lighting control
  • Fluor­es­cent lamps with elec­tron­ical ballast (EB)
    6 x 48 W
  • - uncom­pensated
    500 VA
Fluor­es­cent bulbs control
  • Energy-saving lamps
    13 W
  • Power lighting fluo lamps
    5 x 13W
  • Max. power fluo. duo lamp comp. series
    6 x 48W
LED control
  • Max number of LED/CFL lamps
    5
  • 230V LED lamps
    5 x 13 W
  • Power LED
    65 W
Incan­des­cent bulbs control
  • Max. power with incan­des­cent lamps
    500 W
  • 230 V incan­des­cent lamps and halogen lamps
    500 W
Connec­tion
  • Connec­tion cross-sect. flex­ible conductor
    0,75 / 2,5mm²
  • Connec­tion cross-sect. rigid cable
    0,75 / 2.5mm²
  • Conductor cross-sec­tion (flex­ible)
    0.75…2.5 mm²
  • Conductor cross-sec­tion (rigid)
    0.75…2.5 mm²
  • Number of contacts
    2
  • Bus coup­ling unit
    with integral bus coup­ling unit
  • Type of connec­tion
    with screw terminals
  • Bus connec­tion
    bus connec­tion via pre-assembled cable with bus connec­tion terminal
  • Type of connec­tion
    with screw
Settings
  • Supported config­ur­a­tion modes
    easy, system
  • Setting
    Switching time on change of direc­tion is preset
Scope of delivery
  • Bus connec­tion included
    Yes
Equip­ment
  • Number of outputs
    2
  • Modular expand­ab­ility
    No
Use
  • Differ­en­ti­ation char­ac­ter­istic 3 - Sales
    with screw terminals
Safety
  • REACH conform
    No
  • RoHS conform
    Yes
  • Halogen free
    No
Use condi­tions
  • Oper­ating temper­ature
    -5…45 °C
  • Stor­age/trans­port temper­ature
    -20…70 °C
Iden­ti­fic­a­tion
  • Device family
    TXB
  • Main design line
    KNX

Downloads

  • Product image

    Image TXB692F  | Hager Africa

    Product Image TXB692F

  • Instruction manual

    Image Instruction manuals for TXB692F  | Hager Africa

    Instruction manuals for TXB692F

    PDF
    420 KB
  • Technical information

    Image   | Hager Africa
    PDF
    443 KB
  • KNX product database

    Image Product-Database ETS for TXB692F  | Hager Africa

    Product-Database ETS for TXB692F

    ETS Database for TXB692F

    KNXPROD
    345 KB
  • Declaration of conformity

    Image EU Declaration of conformity for TXB692F  | Hager Africa

    EU Declaration of conformity for TXB692F

    Declaration

    PDF
    127 KB
  • PEP document

    Image Product environmental profile for TXB692F  | Hager Africa

    Product environmental profile for TXB692F

    PDF
    303 KB
  • RoHS report

    Image Pollutant guidelines for TXB692F  | Hager Africa

    Pollutant guidelines for TXB692F

    REACH declaration TXB692F (english)

    PDF
    33 KB
    Image Pollutant guidelines for TXB692F  | Hager Africa

    Pollutant guidelines for TXB692F

    RoHS declaration TXB692F (english)

    PDF
    33 KB
More documentation

Accessories optional

See more

Discover more of this product range

    1
  • 1
    TXB602F - Output module 2x 6A /230V~, flush mounted, KNX
    TXB602F
    Output module 2x 6A /230V~, flush mounted, KNX

Products and solutions

  • Products catalog
  • Energy distribution
  • Energy management
  • Cable management
  • Building automation
  • Wiring accessories
  • Security
  • Reference projects

Contact and support

  • Find your closest wholesaler
  • Contact us
  • How to videos
  • FAQs
    Digital tools
  • Documentation
  • Learning
  • News

Hager Africa & Near East - Who are we

We deliver safe and simple elect­rical solut­ions, from energy distrib­ution and cable manag­ement, to lighting control and building autom­ation systems for comme­rcial and resid­e­ntial buildings. We want to make life on our planet safer, cleaner and more enjo­yable. While being easy to work with, we remain by your side thro­ug­hout the entire project, coope­rating, collabo­rating and co-creating with you.

More about us

Follow us!

  • Cookies
  • Privacy
  • Hagergroup
  • Report a vulnerability

© 2022 Ha­ger Group