OUTPUT 6 -FOLD 16A C-LOAD ADAPTED / NE • TXA606D | Hager
The store will not work correctly in the case when cookies are disabled.
Hager worldwide
  • Contact
  • Products compliant to other standards
Image Logo  | Hager Africa
  • Products in the catalogue
    0
    See all

    No product result ""

      Product categories
      0

      No category result ""

        Search suggestions

        No suggestion result ""

          Results on the website
          0
          See all

          No content result ""

          Menu
          • Products
          • Solutions
            References - all-in-one solutions
            Let yourself be inspired by projects already achieved
            Refe­rence projects
            • Solutions
            • Energy distrib­ution
              References - all-in-one solutions
              Let yourself be inspired by projects already achieved
              Refe­rence projects
            • Energy manag­ement
              References - all-in-one solutions
              Let yourself be inspired by projects already achieved
              Refe­rence projects
            • Wiring acce­s­s­ories
              References - all-in-one solutions
              Let yourself be inspired by projects already achieved
              Refe­rence projects
            • Building autom­ation
              References - all-in-one solutions
              Let yourself be inspired by projects already achieved
              Refe­rence projects
            • Cable manag­ement
              References - all-in-one solutions
              Let yourself be inspired by projects already achieved
              Refe­rence projects
            • Security
              References - all-in-one solutions
              Let yourself be inspired by projects already achieved
              Refe­rence projects
            • See All
          • Inspiration and knowledge
            Sharing our knowledge with you
            Discover all our resources to help you find the right solution for your project
            Down­l­oads
            • Inspiration and knowledge
            • Learning
              • How-to videos
              • E-learning
              • See All
              Sharing our knowledge with you
              Discover all our resources to help you find the right solution for your project
              Down­l­oads
            • Refe­rence projects
              Sharing our knowledge with you
              Discover all our resources to help you find the right solution for your project
              Down­l­oads
            • IEC standard
              Sharing our knowledge with you
              Discover all our resources to help you find the right solution for your project
              Down­l­oads
            • See All
          • Support
            Tools, apps and software
            Our applications and software will support you in your projects
            Learn more
            • Support
            • Find a whol­e­s­aler
              Tools, apps and software
              Our applications and software will support you in your projects
              Learn more
            • FAQ
              Tools, apps and software
              Our applications and software will support you in your projects
              Learn more
            • Down­l­oads
              Tools, apps and software
              Our applications and software will support you in your projects
              Learn more
            • Digital tools
              • Hage­rcad
              • eCat app
              • Hager mood
              • See All
              Tools, apps and software
              Our applications and software will support you in your projects
              Learn more
            • Contact us
              Tools, apps and software
              Our applications and software will support you in your projects
              Learn more
            • See All
          • About us
            Sustain­a­bility for us
            Our path towards a more sustain­able future
            Learn more
            • About us
            • Sustain­a­bility
              Sustain­a­bility for us
              Our path towards a more sustain­able future
              Learn more
            • News­l­etter
              Sustain­a­bility for us
              Our path towards a more sustain­able future
              Learn more
            • Investments
              Sustain­a­bility for us
              Our path towards a more sustain­able future
              Learn more
            • See All
          • See all the categories
          Account
          • Catalog
          • Wiring accessories and Building auto­ma­tion
          • Building auto­ma­tion
          • KNX Easy
          • Switch/blind combi actu­ator
          • 6-gang switch / 3-gang blind/shutter (RMD)
          • TXA606D
          Image  TXA606D of the product Hager Africa | Hager Africa
          Image  TXA606D of the product Hager Africa | Hager Africa
          Image  TXA606D of the product Hager Africa | Hager Africa

          Output module 6x 16A (C)/230V~, KNX

          TXA606D

          Image  TXA606D of the product Hager Africa | Hager Africa
          Image  TXA606D of the product Hager Africa | Hager Africa
          Image  TXA606D of the product Hager Africa | Hager Africa
          • Wiring accessories and Building auto­ma­tion

          Output module 6x 16A (C)/230V~, KNX TXA606D

          EAN
          3250616048843
          Packaging
          1 Piece

          You have to log in with your myHager profile to see prices and to order.

          Add to a list
          Add to a list

          Login to create a product list

          You need to be logged into your myHager account to create product lists

          Create an account Sign in
          • Technical properties
          • Documentations
          • Accessories
          • More products
          Download the data sheet

          Technical properties

          Archi­tec­ture
          • Bus system
            yes
          Func­tions
          • Multi-phase mode
            suit­able to switch different external conductors
          • Func­tion
            with posi­tioning func­tion for blind and lamella posi­tion ; with safety func­tions e.g. for wind, rain, alarm ; with sun shade func­tion
          • Switching
            For switch­ing, e.g. of 6 inde­pendent loads or activ­a­tion of 3 drives
          • Oper­ating mode
            any combined oper­a­tion from drive and switching func­tions possible
          Config­ur­a­tion
          • Number of modules
            4
          Controls and indic­ators
          • Indic­ator lamp
            yes
          • Oper­a­tion
            Manual oper­a­tion can be activ­ated via selec­tion switch, thereby deac­tiv­a­tion of the KNX func­tion
          • Indic­a­tion / display
            status LED integ­rated in the manual oper­a­tion button
          • Manual selec­tion switches / push-but­tons
            manual oper­a­tion buttons for on/off (up/­down) and bus func­tion on/off per chan­nel/device
          • Button / push-button
            with illu­min­ated program­ming button
          Main elec­trical features
          • Rated oper­a­tional voltage Ue
            230 V
          • Frequency
            50/60 Hz
          • Rated current
            16 A
          Voltage
          • Oper­ating voltage over bus
            21…32 V DC
          • Output voltage
            230 V AC
          • System supply voltage
            30V DC via bus
          Elec­tric current
          • Bus current consump­tion (data trans­fer)
            5 mA
          • Bus current consump­tion (idle)
            3 mA
          • Number of entry circuits
            0
          • Maximum through current
            16 A
          • Rated current
            16 A
          Dimen­sions
          • Width of rail mounted device (RMD)
            4 modules
          • Height
            90 mm
          Power
          • Max. power with elec­tronic transfo.
            1200 W
          • Output power
            2300 W
          • Max. switching power
            8625 W
          • Conven­tional trans­formers
            1600 VA
          • Elec­tronic trans­formers
            1200 W
          Lighting control
          • Fluor­es­cent lamps with elec­tron­ical ballast (EB)
            20 x 36 W
          • - uncom­pensated
            1200 W
          Fluor­es­cent bulbs control
          • Energy-saving lamps
            23 W
          • Power lighting fluo lamps
            18x23W
          • Fluor­es­cent lamps parallel compensated
            1500 W /200 µF
          LED control
          • Max number of LED/CFL lamps
            18
          • 230V LED lamps
            18 x 23 W
          • Power LED
            216 W
          • LED
            Status LED integ­rated in manual oper­a­tion button
          Incan­des­cent bulbs control
          • Max. power with incan­des­cent lamps
            2300 W
          • 230 V incan­des­cent lamps and halogen lamps
            2300 W
          Connec­tion
          • Connec­tion cross-sect. flex­ible conductor
            0,75 / 2,5mm²
          • Connec­tion cross-sect. rigid cable
            0,75 / 2.5mm²
          • Type of load
            C-Load
          • Conductor cross-sec­tion (flex­ible)
            0.75…2.5 mm²
          • Conductor cross-sec­tion (rigid)
            0.75…2.5 mm²
          • Type of contacts
            6NO
          • Bus coup­ling unit
            with integral bus coup­ling unit
          • Type of connec­tion
            with Quick­Con­nect plug-in terminals
          • Bus connec­tion
            bus connec­tion via connecting terminal
          • Type of connec­tion
            quick connect
          Settings
          • Supported config­ur­a­tion modes
            easy, system
          • Setting
            Switching time on change of direc­tion is preset
          Scope of delivery
          • Bus connec­tion included
            Yes
          Equip­ment
          • Number of outputs
            6
          • Modular expand­ab­ility
            No
          Use
          • Differ­en­ti­ation char­ac­ter­istic 3 - Sales
            with plug-in terminals
          Safety
          • REACH conform
            No
          • RoHS conform
            Yes
          • Halogen free
            No
          Use condi­tions
          • Oper­ating temper­ature
            -5…45 °C
          • Stor­age/trans­port temper­ature
            -20…70 °C
          Iden­ti­fic­a­tion
          • Device family
            TXA
          • Main design line
            KNX

          Downloads

          • Product image

            Image TXA606D  | Hager Africa

            Product Image TXA606D

          • ProductNotice

            Image Instruction manuals for TXA606D  | Hager Africa

            Instruction manuals for TXA606D

            PDF
            1 MB
          • ProductETSBase

            Image Product-Database ETS for TXA606D  | Hager Africa

            Product-Database ETS for TXA606D

            ETS Database for TXA606B

            KNXPROD
            542 KB
          • ProductApplicationDescription

            Image Application guides ETS / easy link for TXA606D  | Hager Africa

            Application guides ETS / easy link for TXA606D

            Application description TXM616D

            PDF
            9 MB
          • ProductECDeclaration

            Image EU Declaration of conformity for TXA606D  | Hager Africa

            EU Declaration of conformity for TXA606D

            Declaration

            PDF
            39 KB
          • ProductEnvironmentProfile

            Image Product environmental profile for TXA606D  | Hager Africa

            Product environmental profile for TXA606D

            PDF
            311 KB
            Image Product environmental profile for TXA606D  | Hager Africa

            Product environmental profile for TXA606D

            PDF
            307 KB
          • ProductROHS

            Image Pollutant guidelines for TXA606D  | Hager Africa

            Pollutant guidelines for TXA606D

            REACH declaration TXA606D (english)

            PDF
            33 KB
            Image Pollutant guidelines for TXA606D  | Hager Africa

            Pollutant guidelines for TXA606D

            RoHS declaration TXA606D (english)

            PDF
            33 KB
          More documentation

          Accessories optional

          See more

          Discover more of this product range

            1
          • 1
            TXA606B - Output module 4x 10A /230V~, KNX
            TXA606B
            Output module 4x 10A /230V~, KNX

          Products and solutions

          • Products catalog
          • Energy distribution
          • Energy management
          • Cable management
          • Building automation
          • Wiring accessories
          • Security
          • Reference projects

          Contact and support

          • Find your closest wholesaler
          • Contact us
          • How to videos
          • FAQs
            Digital tools
          • Documentation
          • Learning
          • News

          Hager Africa & Near East - Who are we

          We deliver safe and simple elect­rical solut­ions, from energy distrib­ution and cable manag­ement, to lighting control and building autom­ation systems for comme­rcial and resid­e­ntial buildings. We want to make life on our planet safer, cleaner and more enjo­yable. While being easy to work with, we remain by your side thro­ug­hout the entire project, coope­rating, collabo­rating and co-creating with you.

          More about us

          Follow us!

          • Cookies
          • Privacy
          • Hagergroup
          • Report a vulnerability

          © 2022 Ha­ger Group