MCCB X250 4P 40kA 160A TM • HNB161H | Hager
The store will not work correctly in the case when cookies are disabled.
Hager worldwide
  • Contact
  • Products compliant to other standards
Image Logo  | Hager Africa
Menu
  • Products
  • Solutions
    References - all-in-one solutions
    Let yourself be inspired by projects already achieved
    Refe­rence projects
    • Solutions
    • Energy distrib­ution
      References - all-in-one solutions
      Let yourself be inspired by projects already achieved
      Refe­rence projects
    • Energy manag­ement
      References - all-in-one solutions
      Let yourself be inspired by projects already achieved
      Refe­rence projects
    • Wiring acce­s­s­ories
      References - all-in-one solutions
      Let yourself be inspired by projects already achieved
      Refe­rence projects
    • Building autom­ation
      References - all-in-one solutions
      Let yourself be inspired by projects already achieved
      Refe­rence projects
    • Cable manag­ement
      References - all-in-one solutions
      Let yourself be inspired by projects already achieved
      Refe­rence projects
    • Security
      References - all-in-one solutions
      Let yourself be inspired by projects already achieved
      Refe­rence projects
    • See All
  • Inspiration and knowledge
    Sharing our knowledge with you
    Discover all our resources to help you find the right solution for your project
    Down­l­oads
    • Inspiration and knowledge
    • Learning
      • How-to videos
      • E-learning
      • See All
      Sharing our knowledge with you
      Discover all our resources to help you find the right solution for your project
      Down­l­oads
    • Refe­rence projects
      Sharing our knowledge with you
      Discover all our resources to help you find the right solution for your project
      Down­l­oads
    • IEC standard
      Sharing our knowledge with you
      Discover all our resources to help you find the right solution for your project
      Down­l­oads
    • See All
  • Support
    Tools, apps and software
    Our applications and software will support you in your projects
    Learn more
    • Support
    • Find a whol­e­s­aler
      Tools, apps and software
      Our applications and software will support you in your projects
      Learn more
    • FAQ
      Tools, apps and software
      Our applications and software will support you in your projects
      Learn more
    • Down­l­oads
      Tools, apps and software
      Our applications and software will support you in your projects
      Learn more
    • Digital tools
      • Hage­rcad
      • eCat app
      • Hager mood
      • See All
      Tools, apps and software
      Our applications and software will support you in your projects
      Learn more
    • Contact us
      Tools, apps and software
      Our applications and software will support you in your projects
      Learn more
    • See All
  • About us
    Sustain­a­bility for us
    Our path towards a more sustain­able future
    Learn more
    • About us
    • Sustain­a­bility
      Sustain­a­bility for us
      Our path towards a more sustain­able future
      Learn more
    • News­l­etter
      Sustain­a­bility for us
      Our path towards a more sustain­able future
      Learn more
    • Investments
      Sustain­a­bility for us
      Our path towards a more sustain­able future
      Learn more
    • See All
  • See all the categories
Account
  • Catalog
  • Energy distri­bu­tion
  • Main incomers
  • h3 MCCBs
  • x250 / h250 MCCBs
  • MCCBs x250 4 pole 40 kA TM
  • HNB161H
Image  HNB161H of the product Hager Africa | Hager Africa
Image  HNB161H of the product Hager Africa | Hager Africa

Moulded Case Circuit Breaker X250 4P 40kA 160A TM

HNB161H

Image  HNB161H of the product Hager Africa | Hager Africa
Image  HNB161H of the product Hager Africa | Hager Africa
  • Energy distri­bu­tion

Moulded Case Circuit Breaker X250 4P 40kA 160A TM HNB161H

EAN
3250613347802
Packaging
1 Piece

You have to log in with your myHager profile to see prices and to order.

Add to a list
Add to a list

Login to create a product list

You need to be logged into your myHager account to create product lists

Create an account Sign in
  • Technical properties
  • Documentations
  • Accessories
  • More products
Download the data sheet

Technical properties

Archi­tec­ture
  • Type of order
    Toggle
  • Neutral posi­tion
    left
  • Number of poles
    4 P
  • Type of pole
    4P4D N:0/100%
Func­tions
  • Complete device with protec­tion unit
    Yes
  • Trip Unit
    TM A/A
  • With integ­rated earth leakage fault protec­tion
    No
Main elec­trical features
  • Rated oper­a­tional voltage Ue
    220 / 415 V
  • Frequency
    50/60 Hz
Voltage
  • Rated insu­la­tion voltage
    800 V
  • Rated impulse with­stand voltage
    8 kV
  • With under voltage release
    No
Elec­tric current
  • Rated current
    160 A
  • Thermal protec­tion nob setting xIN
    0.63 / 0.8 / 1
  • Breaking capa­city on 1 pole for IT 400V NF 60947-2
    9 kA
  • Rated ulti­mate short-­cir­cuit breaking capa­city Icu under 230V AC IEC 60947-2
    85 kA
  • Rated ulti­mate short-­cir­cuit breaking capa­city Icu under 400V AC IEC 60947-2
    40 kA
  • Rated ulti­mate short-­cir­cuit breaking capa­city Icu under 415V AC IEC 60947-2
    40 kA
Current correc­tion factors
  • Correc­tion factor of rating current for 2 devices placed side-by-side
    1
  • Correc­tion factor of rating current for 3 devices placed side-by-side
    1
  • Correc­tion factor of rating current for 4 and 5 devices placed side-by-side
    1
  • Correc­tion factor of rating current for 6 devices placed side-by-side
    1
Power
  • Total power loss under IN
    32.6 W
  • Power loss per pole at In
    10.9 W
Trip­ping
  • Trip­mode
    TM
  • Time of response when opening
    10 ms
Endur­ance
  • Elec­tric endur­ance in number of cycles
    1000
  • Number of mech­an­ical oper­a­tions
    4000
Install­a­tion, mounting
  • DIN rail mounting with optional adapt­ator
    Yes
Connec­tion
  • Connec­tion cross-sect. flex­ible conductor
    35 / 150mm²
  • Connec­tion cross-sect. rigid cable
    35 / 185mm²
  • Connec­tion
    Front connec­tion
  • Type of connec­tion
    Terminal
Settings
  • Range of the magnetic adjust­ment
    960 / 1280 / 1600 / 2080 A
Equip­ment
  • Number of auxil­iary contacts as normally closed contact
    0
  • Number of auxil­iary contacts as normally open contact
    0
  • Number of auxil­iary contacts as change-over contact
    0
  • Motor drive optional
    Yes
Use cases
  • Category of use
    A
Stand­ards
  • Standard text
    IEC 60947-2
  • European directive WEEE
    concerned
Safety
  • REACH conform
    Yes
  • RoHS conform
    Yes
  • Halogen free
    No
Use condi­tions
  • Oper­ating temper­ature
    -25…70 °C
  • Alti­tude
    2000 m
  • Air humidity protec­tion
    for all climates
  • Stor­age/trans­port temper­ature
    -35…70 °C

Downloads

  • Product image

    Image HNB161H  | Hager Africa

    Product Image HNB161H

  • ProductNotice

    Image Instruction manuals for HNB161H  | Hager Africa

    Instruction manuals for HNB161H

    PDF
    9 MB
  • ProductECDeclaration

    Image EU Declaration of conformity for HNB161H  | Hager Africa

    EU Declaration of conformity for HNB161H

    EU Declaration of Conformity

    PDF
    326 KB
    Image EU Declaration of conformity for HNB161H  | Hager Africa

    EU Declaration of conformity for HNB161H

    Declaration

    PDF
    811 KB
    Image EU Declaration of conformity for HNB161H  | Hager Africa

    EU Declaration of conformity for HNB161H

    Declaration

    PDF
    493 KB
    Image EU Declaration of conformity for HNB161H  | Hager Africa

    EU Declaration of conformity for HNB161H

    UKCA Declaration of Conformity

    PDF
    329 KB
  • ProductEnvironmentProfile

    Image Product environmental profile for HNB161H  | Hager Africa

    Product environmental profile for HNB161H

    PDF
    435 KB
  • ProductROHS

    Image Pollutant guidelines for HNB161H  | Hager Africa

    Pollutant guidelines for HNB161H

    RoHS declaration HNB161H (english)

    PDF
    33 KB
    Image Pollutant guidelines for HNB161H  | Hager Africa

    Pollutant guidelines for HNB161H

    REACH declaration HNB161H (english)

    PDF
    32 KB
More documentation

Accessories optional

See more

Discover more of this product range

    5
  • 1
    HNB101Z - Moulded Case Circuit Breaker x250 4P 40kA 100A TM
    HNB101Z
    Moulded Case Circuit Breaker x250 4P 40kA 100A TM
  • 2
    HNB126Z - Moulded Case Circuit Breaker x250 4P 40kA 125A TM
    HNB126Z
    Moulded Case Circuit Breaker x250 4P 40kA 125A TM
  • 3
    HNB161Z - Moulded Case Circuit Breaker x250 4P 40kA 160A TM
    HNB161Z
    Moulded Case Circuit Breaker x250 4P 40kA 160A TM
  • 4
    HNB201Z - Moulded Case Circuit Breaker x250 4P 40kA 200A TM
    HNB201Z
    Moulded Case Circuit Breaker x250 4P 40kA 200A TM
  • 5
    HNB101U - Moulded Case Circuit Breaker X250 4P 40kA 100A TM
    HNB101U
    Moulded Case Circuit Breaker X250 4P 40kA 100A TM

Products and solutions

  • Products catalog
  • Energy distribution
  • Energy management
  • Cable management
  • Building automation
  • Wiring accessories
  • Security
  • Reference projects

Contact and support

  • Find your closest wholesaler
  • Contact us
  • How to videos
  • FAQs
    Digital tools
  • Documentation
  • Learning
  • News

Hager Africa & Near East - Who are we

We deliver safe and simple elect­rical solut­ions, from energy distrib­ution and cable manag­ement, to lighting control and building autom­ation systems for comme­rcial and resid­e­ntial buildings. We want to make life on our planet safer, cleaner and more enjo­yable. While being easy to work with, we remain by your side thro­ug­hout the entire project, coope­rating, collabo­rating and co-creating with you.

More about us

Follow us!

  • Cookies
  • Privacy
  • Hagergroup
  • Report a vulnerability

© 2022 Ha­ger Group