Moulded Case Circuit Breaker h3 x630 TM ADJ 4P4D N0-100% 320A 50kA FTC HMJ321DR

EAN-Nr.
3250613199388
Packaging
1 piece

You have to log in with your myHager profile to see prices and to order.

Add to a list
Add to a list

Login to create a product list

You need to be logged into your myHager account to create product lists

Create an account Sign in

Moulded Case Circuit Breaker h3 x630 TM ADJ 4P4D N0-100% 320A 50kA FTC

HMJ321DR

  • Accessories
  • Technical characteristics
  • Environmental value
  • Documentations
  • More products

Complete your system

Optional accessories

  • See more (42)
    • Auxil­i­aries contact block 4 products available
    • AOB MCCB type A 1 products available
    • Handle with inter­lock for power breaker 1 products available
    • Shunt release 5 products available
    • Under voltage coil 8 products available
    • Connec­tion Func­tions 5 products available

    Complete your system

    • Auxil­i­aries contact block
    • AOB MCCB type A
    • Handle with inter­lock for power breaker
    • Shunt release
    • Under voltage coil
    • Connec­tion Func­tions
    • Locking inter­locking func­tions
    • Handle for power circuit breaker
    • Terminal cover
    • Accessor­ies/s­pare parts for low-­voltage switch tech­no­logy
    • Mech­anic accessories for low-­voltage compon­ents
    • Phase separ­a­tion func­tions
    • Chassis power breaker
    • Motor oper­ator
    • HXA026H

      Alarm contact low level 1NO+1NC 125V AC (x160-P160-x250-P250-x630-P630)

      0.00 €  / *
    • HXA021H

      Auxiliary contact 1NO+1NC 250V AC (x160-P160-x250-P250-x630-P630)

      0.00 €  / *
    • HXA024H

      Alarm contact 1NO+1NC 250V AC (x160-P160-x250-P250-x630-P630)

      0.00 €  / *
    • HXA025H

      Auxiliary low level 1NO+1NC 125V AC (x160-P160-x250-P250-x630-P630)

      0.00 €  / *
    • HBW400H

      RCD add on P630 4P 400A Idn adj

      0.00 €  / *
    • HXW032H

      Direct rotary handle for x630/P630, with door lock

      0.00 €  / *
    • HXA003H

      Shunt trip 100-120V AC (x160-P160-x250-P250-x630-P630)

      0.00 €  / *
    • HXA005H

      Shunt trip 380-450V AC (x160-P160-x250-P250-x630-P630)

      0.00 €  / *
    • HXA002H

      Shunt trip 48V DC (x160-P160-x250-P250-x630-P630)

      0.00 €  / *
    • HXA001H

      Shunt trip 24V DC (x160-P160-x250-P250-x630-P630)

      0.00 €  / *
    • HXA004H

      Shunt trip 200-240V AC (x160-P160-x250-P250-x630-P630)

      0.00 €  / *
    • HXA051H

      UVR delayed 24V DC (x160-P160-x250-P250-x630-P630)

      0.00 €  / *
    • HXA015H

      Undervoltage release 380-450V AC (x160-P160-x250-P250-x630-P630)

      0.00 €  / *
    • HXA014H

      Undervoltage release 200-240V AC (x160-P160-x250-P250-x630-P630)

      0.00 €  / *
    • HXA055H

      UVR delayed 380-450V AC (x160-P160-x250-P250-x630-P630)

      0.00 €  / *
    • HXA054H

      UVR delayed 220-240V AC (x160-P160-x250-P250-x630-P630)

      0.00 €  / *
    • HXA011H

      Undervoltage release 24V DC (x160-P160-x250-P250-x630-P630)

      0.00 €  / *
    • HXA053H

      UVR delayed 110-120V AC (x160-P160-x250-P250-x630-P630)

      0.00 €  / *
    • HXA013H

      Undervoltage release 100-120V AC (x160-P160-x250-P250-x630-P630)

      0.00 €  / *
    • HYW328H

      L connection terminal Plug-in (x630/P630) 1P

      0.00 €  / *
    • HYW008H

      Cage terminal x630/P630 Cu/Al 4P 2x 35-300mm²

      0.00 €  / *
    • HYW002H

      Cage terminal x630/P630 Cu/Al 4P 1x 35-300mm²

      0.00 €  / *
    • HYW010H

      Straight terminal extension x630/P630 4P (up to 400A)

      0.00 €  / *
    • HYW012H

      Spread terminal extension x630/P630 4P (up to 400A)

      0.00 €  / *
    • HXA039H

      Padlock (x160-P160-x250-P250-x630)

      0.00 €  / *
    • HXW890H

      Key lock kit for Draw-out kit for x630/P630

      0.00 €  / *
    • HXW066H

      Mechanical interlock front cover x630/P630

      0.00 €  / *
    • HXW031H

      Rotary grey handle on door x/P630

      0.00 €  / *
    • HXW030H

      Direct rotary handle for x630/P630

      0.00 €  / *
    • HYW053H

      Earth plate for Spread terminal extension P630 4P

      0.00 €  / *
    • HYW051H

      Earth plate for Straight terminal extension P630 4P

      0.00 €  / *
    • HYW026H

      Terminal cover for Rear & Plug-in connection x630/P630 4P

      0.00 €  / *
    • HYW024H

      Terminal cover for Spread terminal extension x630/P630 4P

      0.00 €  / *
    • HYW022H

      Terminal cover for Straight terminal extension x630/P630 4P

      0.00 €  / *
    • HZC019

      External locking kit for Ronis EL11AP (125-1600A)

      0.00 €  / *
    • HYW256H

      Safety trip (x630/P630)

      0.00 €  / *
    • HYW019H

      Interphase barrier for x630/P630 3/4P

      0.00 €  / *
    • HYW333H

      Draw-out adaptor for MCCB x630/P630 4P

      0.00 €  / *
    • HYW331H

      Draw-out base 4P x630/P630

      0.00 €  / *
    • HYW301H

      Plug-in adaptor x630/P630 4P

      0.00 €  / *
    • HYW201H

      Plug-in base for x630/P630 4P

      0.00 €  / *
    • HXW042H

      Motor Operator x630/P630 100-240VAC with Auto-Reset

      0.00 €  / *

    Technical characteristics

    Elec­tric current
    • Rated current
      320 A
    • Rated ulti­mate short-­cir­cuit breaking capa­city Icu under 400 V AC IEC 60947-2
      50 kA
    • Rated ulti­mate short-­cir­cuit breaking capa­city Icu under 240 V AC IEC 60947-2
      85 kA
    • Rated service breaking capa­city Ics under 230 V AC according to IEC 60947-2
      85 kA
    • Rated service breaking capa­city Ics under 400 V AC according to IEC 60947-2
      50 kA
    • Rated current 10°C according to IEC 60947
      380,70 A
    • Rated current 15°C according to IEC 60947
      373,60 A
    • Rated current 20°C according to IEC 60947
      366,50 A
    • Rated current 25°C according to IEC 60947
      359,10 A
    • Rated current 30°C according to IEC 60947
      351,70 A
    • Rated current at 35°C according to IEC 60947
      344 A
    • Rated current at 40°C according to IEC 60947
      336,20 A
    • Rated current 45°C according to IEC 60947
      328,20 A
    • Rated current 50°C according to IEC 60947
      320 A
    • Rated current 55°C according to IEC 60947
      311,60 A
    • Rated current at 60°C according to IEC 60947
      302,90 A
    • Rated current 65°C according to IEC 60947
      294 A
    • Rated current 70°C according to IEC 60947
      284,80 A
    Archi­tec­ture
    • Number of poles
      4
    • Control/­op­er­a­tion element
      Toggle
    • Device construc­tion type
      Fixed built-in
    • Neutral posi­tion
      Left
    Trip­ping
    • Response time when opening
      10 ms
    Frequency
    • Frequency
      50 - 60 Hz
    Voltage
    • Rated impulse with­stand voltage Uimp
      8000 V
    • Rated insu­la­tion voltage Ui
      800 V
    • Rated oper­a­tional voltage Ue
      220 - 415 V
    Func­tions
    • Trip unit
      TM A/A
    Power
    • Total power loss under IN
      75 W
    Safety
    • Ingress Protec­tion (IP) class
      IP4X
    Settings
    • Thermal protec­tion knob setting xIN
      0.63, 0.8, 1
    Cable
    • Cable material
      Copper
    Compat­ib­ility
    • Compat­ible with RDC AOB
      Yes
    • Suit­able for DIN Rail
      No
    • Suit­able for distri­bu­tion board
      Yes
    Dimen­sions
    • Height
      260 mm
    • Width
      185 mm
    • Depth
      150 mm
    • Down­stream busbar: width, height, diameter screw (max.)
      10 mm, 12 mm, 32 mm
    • Top stream busbar: width, height, diameter screw (max.)
      10 mm, 12 mm, 32 mm
    Install­a­tion, mounting
    • Mount­ing-/­Con­nec­tion Posi­tion
      Front
    • Nominal tight­ening torque
      18 - 18 Nm
    • Nominal tight­ening torque down terminal
      18 - 18 Nm
    • Nominal tight­ening torque top terminal
      18 - 18 Nm

    Environmental value

    We are committed to bettering our environmental performance by reducing our footprint while acting as a sustainability enabler for our customers. Learn More

    RoHS conform Yes
    REACh-SVHC free Yes

    Certifications and documents

    MCCB h3+ P250 TM 4x250A 40kA
    PDF
    1,78 MB
    Hager REACH declaration HMJ321DR
    PDF
    Hager RoHS report HMJ321DR
    PDF

    Downloads

    • Image HMJ321DR  | Hager

      Product Image HMJ321DR

    • Installation manual

      Image Installation manual International 2024-10-29  | Hager

      Installation manual International 2024-10-29

      PDF
      10,33 MB
    • Catalogue

      Image h3 MCCB catalogue  | Hager

      h3 MCCB catalogue

      Catalogue en-GB 2024-05-07

      PDF
      9,47 MB
    • Handbook

      Image Handbook en-GB 2021-02-26  | Hager

      Handbook en-GB 2021-02-26

      PDF
      26,34 MB
    • Declaration of conformity

      Image EU Declaration of Conformity  | Hager

      EU Declaration of Conformity

      PDF
      588,41 kB
    More documentation

    Discover our other products of this range

      5
    • 1
      HNW631JR - Moulded Case Circuit Breaker h3+ P630 LSI 4P4D N0-50-100% 630A 40kA FTC
      HNW631JR
      Moulded Case Circuit Breaker h3+ P630 LSI 4P4D N0-50-100% 630A 40kA FTC
    • 2
      HHA018Z - Moulded Case Circuit Breaker h3 x160 TM FIX 1P1D  20A 25kA CTC
      HHA018Z
      Moulded Case Circuit Breaker h3 x160 TM FIX 1P1D 20A 25kA CTC
    • 3
      HHA014Z - Moulded Case Circuit Breaker h3 x160 TM FIX 1P1D  16A 25kA CTC
      HHA014Z
      Moulded Case Circuit Breaker h3 x160 TM FIX 1P1D 16A 25kA CTC
    • 4
      HDA160U - Moulded Case Circuit Breaker h3 x160 TM ADJ 3P3D  160A 18kA CTC
      HDA160U
      Moulded Case Circuit Breaker h3 x160 TM ADJ 3P3D 160A 18kA CTC
    • 5
      HDA040U - Moulded Case Circuit Breaker h3 x160 TM ADJ 3P3D  40A 18kA CTC
      HDA040U
      Moulded Case Circuit Breaker h3 x160 TM ADJ 3P3D 40A 18kA CTC

    Products and solutions

    • Product catalogue
    • Energy distribution
    • Energy management
    • Wiring accessories
    • Connected homes

    Contact and Support

    • FAQ
    • How-to videos
    • Downloads
    • Find a distributor
    • Contact us
    • Newsletter

    Who we are

    We deliver safe and simple electrical solutions, from energy distribution to lighting control and building automation systems for commercial and residential buildings. We want to make life on our planet safer, cleaner and more enjoyable. While being easy to work with, we remain by your side throughout the entire project, cooperating, collaborating and co-creating with you.

    More about us

    Fol­low us

    • Privacy
    • Cookies
    • Report a vulnerability

    © Hager Group