MCB 3P 10kA/15kA C-6A 3M • NCN306A | Hager
The store will not work correctly in the case when cookies are disabled.
Hager worldwide
  • Contact
  • Products compliant to other standards
Image Logo  | Hager Africa
  • Products in the catalogue
    0
    See all

    No product result ""

      Product categories
      0

      No category result ""

      Menu
      • Products
      • Solutions
        References - all-in-one solutions
        Let yourself be inspired by projects already achieved
        Refe­rence projects
        • Solutions
        • Energy distrib­ution
          References - all-in-one solutions
          Let yourself be inspired by projects already achieved
          Refe­rence projects
        • Energy manag­ement
          References - all-in-one solutions
          Let yourself be inspired by projects already achieved
          Refe­rence projects
        • Wiring acce­s­s­ories
          References - all-in-one solutions
          Let yourself be inspired by projects already achieved
          Refe­rence projects
        • Building autom­ation
          References - all-in-one solutions
          Let yourself be inspired by projects already achieved
          Refe­rence projects
        • Cable manag­ement
          References - all-in-one solutions
          Let yourself be inspired by projects already achieved
          Refe­rence projects
        • Security
          References - all-in-one solutions
          Let yourself be inspired by projects already achieved
          Refe­rence projects
        • See All
      • Inspiration and knowledge
        Sharing our knowledge with you
        Discover all our resources to help you find the right solution for your project
        Down­l­oads
        • Inspiration and knowledge
        • Learning
          • How-to videos
          • E-learning
          • See All
          Sharing our knowledge with you
          Discover all our resources to help you find the right solution for your project
          Down­l­oads
        • Refe­rence projects
          Sharing our knowledge with you
          Discover all our resources to help you find the right solution for your project
          Down­l­oads
        • IEC standard
          Sharing our knowledge with you
          Discover all our resources to help you find the right solution for your project
          Down­l­oads
        • See All
      • Support
        Tools, apps and software
        Our applications and software will support you in your projects
        Learn more
        • Support
        • Find a whol­e­s­aler
          Tools, apps and software
          Our applications and software will support you in your projects
          Learn more
        • FAQ
          Tools, apps and software
          Our applications and software will support you in your projects
          Learn more
        • Down­l­oads
          Tools, apps and software
          Our applications and software will support you in your projects
          Learn more
        • Digital tools
          • Hage­rcad
          • eCat app
          • Hager mood
          • See All
          Tools, apps and software
          Our applications and software will support you in your projects
          Learn more
        • Contact us
          Tools, apps and software
          Our applications and software will support you in your projects
          Learn more
        • See All
      • About us
        Sustain­a­bility for us
        Our path towards a more sustain­able future
        Learn more
        • About us
        • Sustain­a­bility
          Sustain­a­bility for us
          Our path towards a more sustain­able future
          Learn more
        • News­l­etter
          Sustain­a­bility for us
          Our path towards a more sustain­able future
          Learn more
        • Investments
          Sustain­a­bility for us
          Our path towards a more sustain­able future
          Learn more
        • See All
      • See all the categories
      Account
      • Catalog
      • Energy distri­bu­tion
      • Protec­tion devices
      • MCBs
      • MCBs NCN, NBN, NDN
      • 3 pole, NCN, Curve C, 10 000 A / 15 kA
      • NCN306A
      Image  NCN306A of the product Hager Africa | Hager Africa
      Image  NCN306A of the product Hager Africa | Hager Africa
      Image  NCN306A of the product Hager Africa | Hager Africa

      MCB 3P 10kA/15kA C-6A 3M

      NCN306A

      Image  NCN306A of the product Hager Africa | Hager Africa
      Image  NCN306A of the product Hager Africa | Hager Africa
      Image  NCN306A of the product Hager Africa | Hager Africa
      • Energy distri­bu­tion

      MCB 3P 10kA/15kA C-6A 3M NCN306A

      EAN
      3250614615795
      Packaging
      4 PCEs

      You have to log in with your myHager profile to see prices and to order.

      Add to a list
      Add to a list

      Login to create a product list

      You need to be logged into your myHager account to create product lists

      Create an account Sign in
      • Technical properties
      • Documentations
      • Accessories
      • More products
      Download the data sheet

      Technical properties

      Archi­tec­ture
      • Neutral posi­tion
        without neutral
      • Number of protected poles
        3
      • Number of poles
        3 P
      • Type of pole
        3 P
      • Curve
        C
      Func­tions
      • Concur­rently switching N-neutral
        No
      Config­ur­a­tion
      • Number of modules
        3
      Connectivity
      • Top connec­tion aligne­ment for modular devices
        Aligned terminal
      • Bottom connec­tion aligne­ment for modular devices
        Aligned terminal
      Main elec­trical features
      • Rated short circuit breaking capa­city Icn AC according IEC60898-1
        10 kA
      • Rated oper­a­tional voltage Ue
        400 V
      • Type of supply voltage
        AC
      Voltage
      • Rated insu­la­tion voltage
        500 V
      • Rated impulse with­stand voltage
        6000 V
      • Minimum threshold voltage (Ue min)
        12 V
      Elec­tric current
      • Rated current
        6 A
      • Rated service breaking capa­city Ics AC according IEC 60898-1
        7.5 kA
      • min/maxi threshold value of the AC thermal oper­a­tion
        1.13 / 1.45 In
      • Magnetic regu­lating currrent
        5 / 10 In
      • min/maxi threshold value of the DC magnetic oper­a­tion
        7 / 15 In
      • min/maxi threshold value of the DC thermal oper­a­tion
        1.13 / 1.45 In
      • Rating current -10°C according to IEC 60947
        8.17 A
      • Rating current -15°C according to IEC 60947
        8.33 A
      • Rating current -20°C according to IEC 60947
        8.48 A
      • Rating current -25°C according to IEC 60947
        8.63 A
      • Rating current -5°C according to IEC 60947
        8.01 A
      • Rating current 0°C according to IEC 60947
        7.85 A
      • Rating current 10°C according to IEC 60947
        7.52 A
      • Rating current 15°C according to IEC 60947
        7.35 A
      • Rating current 20°C according to IEC 60947
        7.17 A
      • Rating current 25°C according to IEC 60947
        6.99 A
      • Rating current 30°C according to IEC 60947
        6.8 A
      • Rating current 35°C according to IEC 60947
        6.61 A
      • Rating current 40°C according to IEC 60947
        6.41 A
      • Rating current 45°C according to IEC 60947
        6.21 A
      • Rating current 5°C according to IEC 60947
        7.69 A
      • Rating current 50°C according to IEC 60947
        6 A
      • Rating current 55°C according to IEC 60947
        5.74 A
      • Rating current 60°C according to IEC 60947
        5.48 A
      • Rating current 65°C according to IEC 60947
        5.19 A
      • Rating current 70°C according to IEC 60947
        4.9 A
      • Rated short circuit breaking capa­city Icn under 230V AC according IEC60898-1
        10 kA
      • Rated short circuit breaking capa­city Icn under 400V AC according IEC60898-1
        10 kA
      • Rated ulti­mate short-­cir­cuit breaking capa­city Icu under 230V AC IEC 60947-2
        30 kA
      • Rated ulti­mate short-­cir­cuit breaking capa­city Icu under 240V AC IEC 60947-2
        30 kA
      • Rated ulti­mate short-­cir­cuit breaking capa­city Icu under 400V AC IEC 60947-2
        15 kA
      • Rated ulti­mate short-­cir­cuit breaking capa­city Icu under 415V AC IEC 60947-2
        15 kA
      • Rated short circuit breaking capa­city Icn under 240V AC according IEC 60898-1
        10 kA
      • Rated short circuit breaking capa­city Icn under 415V AC according IEC 60898-1
        10 kA
      • Rated ulti­mate short-­cir­cuit breaking capa­city Icu under 220V AC IEC 60947-2
        30 kA
      • Rated ulti­mate short-­cir­cuit breaking capa­city Icu under 380V AC IEC 60947-2
        15 kA
      Elec­tric current / temper­ature
      • Rating current -25°C
        7.61 A
      • Rating current -20°C
        7.48 A
      • Rating current -15°C
        7.35 A
      • Rating current -10°C
        7.21 A
      • Rating current -5°C
        7.07 A
      • Rating current 0°C
        6.93 A
      • Rating current 5°C
        6.78 A
      • Rating current 10°C
        6.63 A
      • Rating current 25°C
        6.16 A
      • Rating current 30°C
        6 A
      • Rating current 35°C
        5.81 A
      • Rating current 40°C
        5.61 A
      • Rating current 45°C
        5.41 A
      • Rating current 50°C
        5.19 A
      • Rating current 55°C
        4.97 A
      • Rating current 60°C
        4.74 A
      • Rating current 65°C
        4.5 A
      • Rating current 70°C
        4.24 A
      Current correc­tion factors
      • Correc­tion factor of rating current for 2 devices placed side-by-side
        1
      • Correc­tion factor of rating current for 3 devices placed side-by-side
        0.95
      • Correc­tion factor of rating current for 4 and 5 devices placed side-by-side
        0.9
      • Correc­tion factor of rating current for 6 devices placed side-by-side
        0.85
      • Correc­tion factor of magnetic trip­ping with 100 Hz
        1.1
      • Correc­tion factor of magnetic trip­ping with 200 Hz
        1.2
      • Correc­tion factor of magnetic trip­ping with 400 Hz
        1.5
      • Correc­tion factor of magnetic trip­ping with 60 Hz
        1.1
      Dimen­sions
      • Depth of installed product
        70 mm
      • Height of installed product
        83 mm
      • Width of installed product
        52.5 mm
      Frequency
      • Frequency
        50 to 60 Hz
      Power
      • Maximum power loss per pole according to the product standard
        3 W
      • Total power loss under IN
        4.06 W
      • Power loss per pole at In
        1.36 W
      Endur­ance
      • Elec­tric endur­ance in number of cycles
        4000
      • Number of mech­an­ical oper­a­tions
        20000
      Install­a­tion, mounting
      • Type of top connec­tion for modular devices
        with screw
      • Tight­ening torque
        2,8Nm
      • Type of top rail clip for modular devices
        NA
      • Type of bottom rail clip for modular devices
        plastic
      • Type of Bottom Connec­tion for modular devices
        BIcon­nect
      • Top remov­ab­ility for modular devices
        Yes
      • Bottom remov­ab­ility for modular devices
        Yes
      • Suit­able for flush-­mounting
        Yes
      Connec­tion
      • Connec­tion cross-sec­tion at output with screw, for flex­ible conductor
        1 / 25 mm²
      • Connec­tion cross-sec­tion at output with screw, for massive conductor
        1 / 35 mm²
      • Connec­tion cross-sec­tion for rigid conductor, upstream terminals with screws
        1 / 35 mm²
      • Connec­tion cross-sec­tion of the access with screws, with flex­ible conductor
        1 / 25 mm²
      • Down­stream cage clamp delivery status
        opened
      • Upstream cage clamp delivery status
        opened
      Equip­ment
      • Can be access­or­ized
        Yes
      Stand­ards
      • Standard text
        EN 60898-1 ; IEC 60947-2
      • European directive WEEE
        concerned
      Safety
      • REACH conform
        No
      • RoHS conform
        Yes
      • Halogen free
        No
      Use condi­tions
      • Oper­ating temper­ature
        -25…70 °C
      • Degree of pollu­tion according to IEC 60664 / IEC 60947-2
        2
      • Class of energy limit­a­tion I²t
        3
      • Alti­tude
        2000 m
      • Stor­age/trans­port temper­ature
        -25…80 °C
      temper­atur
      • Temper­ature of calib­ra­tion
        50 °C

      Downloads

      • Product image

        Image NCN306A  | Hager Africa

        Product Image NCN306A

      • ProductDataSheet

        Image Product data sheets for NCN306A  | Hager Africa

        Product data sheets for NCN306A

        UK_PD_TDS_TransformerMotorprotection.pdf

        PDF
        204 KB
      • ProductLicence

        Image Product licence for NCN306A  | Hager Africa

        Product licence for NCN306A

        Licence for UNITED_KINGDOM

        PDF
        243 KB
        Image Product licence for NCN306A  | Hager Africa

        Product licence for NCN306A

        Licence for ITALY

        PDF
        525 KB
      • ProductECDeclaration

        Image EU Declaration of conformity for NCN306A  | Hager Africa

        EU Declaration of conformity for NCN306A

        Declaration

        PDF
        710 KB
        Image EU Declaration of conformity for NCN306A  | Hager Africa

        EU Declaration of conformity for NCN306A

        UKCA Declaration of Conformity

        PDF
        653 KB
        Image EU Declaration of conformity for NCN306A  | Hager Africa

        EU Declaration of conformity for NCN306A

        Declaration

        PDF
        689 KB
        Image EU Declaration of conformity for NCN306A  | Hager Africa

        EU Declaration of conformity for NCN306A

        EU Declaration of Conformity

        PDF
        650 KB
        Image EU Declaration of conformity for NCN306A  | Hager Africa

        EU Declaration of conformity for NCN306A

        Declaration

        PDF
        786 KB
        Image EU Declaration of conformity for NCN306A  | Hager Africa

        EU Declaration of conformity for NCN306A

        Declaration

        PDF
        716 KB
      • ProductEnvironmentProfile

        Image Product environmental profile for NCN306A  | Hager Africa

        Product environmental profile for NCN306A

        PEP - MCB 1P 6kA B-16A, 1 module (english)

        PDF
        9 MB
        Image Product environmental profile for NCN306A  | Hager Africa

        Product environmental profile for NCN306A

        PDF
        432 KB
      • ProductROHS

        Image Pollutant guidelines for NCN306A  | Hager Africa

        Pollutant guidelines for NCN306A

        RoHS declaration NCN306A (english)

        PDF
        103 KB
      More documentation

      Accessories optional

      See more

      Discover more of this product range

        5
      • 1
        NCN300A - MCB 3P 10kA/15kA C-0.5A 3M
        NCN300A
        MCB 3P 10kA/15kA C-0.5A 3M
      • 2
        NCN301A - MCB 3P 10kA/15kA C-1A 3M
        NCN301A
        MCB 3P 10kA/15kA C-1A 3M
      • 3
        NCN302A - MCB 3P 10kA/15kA C-2A 3M
        NCN302A
        MCB 3P 10kA/15kA C-2A 3M
      • 4
        NCN303A - MCB 3P 10kA/15kA C-3A 3M
        NCN303A
        MCB 3P 10kA/15kA C-3A 3M
      • 5
        NCN304A - MCB 3P 10kA/15kA C-4A 3M
        NCN304A
        MCB 3P 10kA/15kA C-4A 3M

      Products and solutions

      • Products catalog
      • Energy distribution
      • Energy management
      • Cable management
      • Building automation
      • Wiring accessories
      • Security
      • Reference projects

      Contact and support

      • Find your closest wholesaler
      • Contact us
      • How to videos
      • FAQs
        Digital tools
      • Documentation
      • Learning
      • News

      Hager Africa & Near East - Who are we

      We deliver safe and simple elect­rical solut­ions, from energy distrib­ution and cable manag­ement, to lighting control and building autom­ation systems for comme­rcial and resid­e­ntial buildings. We want to make life on our planet safer, cleaner and more enjo­yable. While being easy to work with, we remain by your side thro­ug­hout the entire project, coope­rating, collabo­rating and co-creating with you.

      More about us

      Follow us!

      • Cookies
      • Privacy
      • Hagergroup
      • Report a vulnerability

      © 2022 Ha­ger Group