Load break switch 4P 40A • HAB404 | Hager
The store will not work correctly in the case when cookies are disabled.
Hager worldwide
  • Contact
  • Products compliant to other standards
Image Logo  | Hager Africa
Menu
  • Products
  • Solutions
  • Inspiration and knowledge
  • Support
  • About us
Account
  • Catalog
  • Energy distri­bu­tion
  • Main incomers
  • Load break switches
  • Load break switches visual breaking 20 to 125A
  • Load break switches visual breaking 4 pole
  • HAB404
Current search
Image Filter  | Hager Africa Filter
Image Filter  | Hager Africa Filter
ProductsShow

Most popular products

5
1
HAB402 - Load break switch 4P 20A
HAB402
Load break switch 4P 20A
2
HAC410 - Load break switch 4P 100A
HAC410
Load break switch 4P 100A
3
HAD410 - Load break switch  4P 100A
HAD410
Load break switch 4P 100A
4
HAD412 - Load break switch  4P 125A
HAD412
Load break switch 4P 125A
5
HAB406 - Load break switch 4P 63A
HAB406
Load break switch 4P 63A

Load break switch 4P 40A

HAB404

  • Energy distri­bu­tion

Load break switch 4P 40A HAB404

EAN
3250613140359
Packaging
1 Piece

You have to log in with your myHager profile to see prices and to order.

Add to a list
Add to a list

Login to create a product list

You need to be logged into your myHager account to create product lists

Create an account Sign in
  • Technical properties
  • Documentations
  • Accessories
  • More products
Download the data sheet

Technical properties

Archi­tec­ture
  • Type of order
    Short thum­b-­grip
  • Number of poles
    4 P
  • Type of pole
    4 P
  • Type of case
    Fixed built-in
Func­tions
  • Reversing switch
    No
Config­ur­a­tion
  • Number of modules
    3.42
Controls and indic­ators
  • Motor drive integ­rated
    No
Main elec­trical features
  • Rated oper­a­tional voltage Ue
    380 / 415 V
  • Frequency
    50 Hz
Voltage
  • Rated insu­la­tion voltage
    800 V
  • Rated impulse with­stand voltage
    8000 V
Elec­tric current
  • Rated oper­a­tional current in AC21c­at­egory B
    40 A
  • Rated current
    40 A
  • Short-­cir­cuit current with gI-gG fuses
    50 kA
  • Rated short-­time with­stand current 1s
    1.26 kA
  • Accept­able current rating with AC22 category B
    40 A
  • Rated oper­a­tional current in AC23 category A
    40 A
  • Accept­able current rating with AC23 category B
    40 A
Power
  • Total power loss under IN
    3.6 W
  • Power loss per pole at In
    0.9 W
  • Contact rating with 400 V in AC1
    26 kW
Cover, door
  • Inter­lock­able
    Yes
Install­a­tion, mounting
  • Tight­ening torque
    2 - 2.2 Nm
Connec­tion
  • Connec­tion cross-sect. rigid cable
    16mm²
  • Type of connec­tion
    with screw
Equip­ment
  • Number of auxil­iary contacts as normally closed contact
    0
  • Number of auxil­iary contacts as normally open contact
    0
  • Number of auxil­iary contacts as change-over contact
    0
  • Motor drive optional
    No
Stand­ards
  • Standard text
    IEC 60947-3
Safety
  • REACH conform
    Yes
  • RoHS conform
    Yes
  • Halogen free
    No
Use condi­tions
  • Oper­ating temper­ature
    -20…70 °C

Downloads

  • Product image

    Image HAB404  | Hager Africa

    Product Image HAB404

  • ProductNotice

    Image Instruction manuals for HAB404  | Hager Africa

    Instruction manuals for HAB404

    PDF
    1 MB
  • ProductECDeclaration

    Image EU Declaration of conformity for HAB404  | Hager Africa

    EU Declaration of conformity for HAB404

    Declaration

    PDF
    835 KB
    Image EU Declaration of conformity for HAB404  | Hager Africa

    EU Declaration of conformity for HAB404

    Declaration

    PDF
    634 KB
  • ProductROHS

    Image Pollutant guidelines for HAB404  | Hager Africa

    Pollutant guidelines for HAB404

    REACH declaration HAB404 (english)

    PDF
    32 KB
    Image Pollutant guidelines for HAB404  | Hager Africa

    Pollutant guidelines for HAB404

    RoHS declaration HAB404 (english)

    PDF
    33 KB
More documentation

Accessories optional

See more

Discover more of this product range

    5
  • 1
    HAB402 - Load break switch 4P 20A
    HAB402
    Load break switch 4P 20A
  • 2
    HAB403 - Load break switch 4P 32A
    HAB403
    Load break switch 4P 32A
  • 3
    HAB406 - Load break switch 4P 63A
    HAB406
    Load break switch 4P 63A
  • 4
    HAC406 - Load break switch 4P 63A
    HAC406
    Load break switch 4P 63A
  • 5
    HAC408 - Load break switch 4P 80A
    HAC408
    Load break switch 4P 80A

Products and solutions

  • Products catalog
  • Energy distribution
  • Energy management
  • Cable management
  • Building automation
  • Wiring accessories
  • Security
  • Reference projects

Contact and support

  • Find your closest wholesaler
  • Contact us
  • How to videos
  • FAQs
    Digital tools
  • Documentation
  • Learning
  • News

Hager Africa & Near East - Who are we

We deliver safe and simple elect­rical solut­ions, from energy distrib­ution and cable manag­ement, to lighting control and building autom­ation systems for comme­rcial and resid­e­ntial buildings. We want to make life on our planet safer, cleaner and more enjo­yable. While being easy to work with, we remain by your side thro­ug­hout the entire project, coope­rating, collabo­rating and co-creating with you.

More about us

Follow us!

  • Cookies
  • Privacy
  • Hagergroup
  • Report a vulnerability

© 2022 Ha­ger Group