1Ph kWhmeter direct 3x80A 4M S0 • ECP180T | Hager
The store will not work correctly in the case when cookies are disabled.
Hager worldwide
  • Contact
  • Products compliant to other standards
Image Logo  | Hager Africa
Menu
  • Products
  • Solutions
  • Inspiration and knowledge
  • Support
  • About us
Account
  • Catalog
  • Energy manage­ment
  • Energy counting and meas­ure­ment
  • Energy meters
  • Ener­gy­meters
  • New ener­gy­meters (MID)
  • ECP180T

1 Phase kWhmeter direct 3x80A 4M S0

ECP180T

  • Energy manage­ment

1 Phase kWhmeter direct 3x80A 4M S0 ECP180T

EAN
3250612230402
Packaging
1 Piece

You have to log in with your myHager profile to see prices and to order.

Login to create a product list

You need to be logged into your myHager account to create product lists

Create an account Sign in

This product is now obsolete. However, this page remains available for information purposes. If you require any further information for an alternative solution please contact your closest Hager official distributor. Closest wholesaler


  • Technical properties
  • Documentations
  • More products
Download the data sheet

Technical properties

Archi­tec­ture
  • Number of poles
    2 P
  • Type of pole
    3x 1P+N
Func­tions
  • Preci­sion class
    B
  • Tarif type
    T1...T2 (230 V AC) / -
Config­ur­a­tion
  • Number of modules
    4
Compat­ib­ility
  • Suit­able for
    Purchase / supply
Main elec­trical features
  • Rated oper­a­tional voltage Ue
    92 / 276 V
  • Type of supply voltage
    AC
  • Frequency
    50 Hz
Voltage
  • Max oper­ating voltage
    300 V
  • Rated impulse with­stand voltage
    6 kV
Elec­tric current
  • Minimum oper­ating current
    0.015 A
  • Oper­ating current
    0.015 / 80 A
  • Rated current
    80 A
  • Refer­ence current
    5 A
  • Max. meas­ure­ment circuit current
    80 A
Dimen­sions
  • Depth of installed product
    60 mm
  • Height of installed product
    92 mm
  • Width of installed product
    72 mm
Power
  • Power consumed
    2 VA
  • Total power loss under IN
    1 W
  • Plage Impul­sion/KWh
    1 / 1000 Imp/kWh
Elec­trical specific­a­tions
  • Type of pulse gener­ator
    élec­trical
Meas­ure­ment
  • Frequency meas­uring range
    45 to 65 Hz
  • Type of meas­uring instru­ment
    elec­tron­ical
  • Prin­ciple of meas­ure­ment
    Direct meas­ure­ment
Power supply
  • Supply voltage
    230 V ± 20%
Install­a­tion, mounting
  • Tight­ening torque
    2Nm
  • Mounting type
    din-Rail
Connec­tion
  • Wire cross section of metering entrance wire
    33 mm²
  • Wire cross section of metering outgoing wire
    33 mm²
Settings
  • Value of a pulse
    100 Wh
Equip­ment
  • Type of display
    retro illu­min­ated display
  • Tariff model of kilo­wat­t-hour meter
    Externa
  • Type of counter
    three-­point system
Use
  • Pulse dura­tion
    30 / 100 ms
Stand­ards
  • Standard text
    IEC 62053-21 / 23 ; IEC 61557-12
  • European directive WEEE
    concerned
Use condi­tions
  • Oper­ating temper­ature
    -25…55 °C
  • Degree of pollu­tion according to IEC 60664 / IEC 60947-2
    2
  • Alti­tude
    2000 m
  • Stor­age/trans­port temper­ature
    -25…70 °C

Downloads

  • Product image

    Image ECP180T  | Hager Africa

    Product Image ECP180T

  • ProductNotice

    Image Instruction manuals for ECP180T  | Hager Africa

    Instruction manuals for ECP180T

    PDF
    1 MB
  • ProductECDeclaration

    Image EU Declaration of conformity for ECP180T  | Hager Africa

    EU Declaration of conformity for ECP180T

    Declaration

    PDF
    110 KB
  • ProductEnvironmentProfile

    Image Product environmental profile for ECP180T  | Hager Africa

    Product environmental profile for ECP180T

    PDF
    429 KB
  • ProductROHS

    Image Pollutant guidelines for ECP180T  | Hager Africa

    Pollutant guidelines for ECP180T

    RoHS declaration ECP180T (english)

    PDF
    103 KB
More documentation

Discover more of this product range

    5
  • 1
    ECN140D - 1 Phase kWhmeter direct 40A 1M
    ECN140D
    1 Phase kWhmeter direct 40A 1M
  • 2
    ECP140D - 1 Phase kWhmeter direct 40A 1M S0 MID
    ECP140D
    1 Phase kWhmeter direct 40A 1M S0 MID
  • 3
    ECP180D - 1 Phase kWhmeter direct 80A 2M S0 MID
    ECP180D
    1 Phase kWhmeter direct 80A 2M S0 MID
  • 4
    ECP300C - 3 Phase kWhmeter via CT 1A or 5A 4M S0 MID
    ECP300C
    3 Phase kWhmeter via CT 1A or 5A 4M S0 MID
  • 5
    ECP310D - 3 Phase kWhmeter direct 125A 6M S0 MID
    ECP310D
    3 Phase kWhmeter direct 125A 6M S0 MID

Products and solutions

  • Products catalog
  • Energy distribution
  • Energy management
  • Cable management
  • Building automation
  • Wiring accessories
  • Security
  • Reference projects

Contact and support

  • Find your closest wholesaler
  • Contact us
  • How to videos
  • FAQs
    Digital tools
  • Documentation
  • Learning
  • News

Hager Africa & Near East - Who are we

We deliver safe and simple elect­rical solut­ions, from energy distrib­ution and cable manag­ement, to lighting control and building autom­ation systems for comme­rcial and resid­e­ntial buildings. We want to make life on our planet safer, cleaner and more enjo­yable. While being easy to work with, we remain by your side thro­ug­hout the entire project, coope­rating, collabo­rating and co-creating with you.

More about us

Follow us!

  • Cookies
  • Privacy
  • Hagergroup
  • Report a vulnerability

© 2022 Ha­ger Group