    • SPL265R
    EAN-Nr.
    3250615515742
    Packaging
    1 piece
    • Surge Protec­tion Device (SPD)

    SPD 2P T2 TNS/TT Uc 350V In 35kA Imax 65kA remote contact SPL265R

    Add to a list
    Add to a list

    Login to create a product list

    You need to be logged into your myHager account to create product lists

    Create an account Sign in

    SPD 2P T2 TNS/TT Uc 350V In 35kA Imax 65kA remote contact

    SPL265R

    • Technical characteristics
    • Environmental value
    • Documentations
    • More products

    Technical characteristics

    Archi­tec­ture
    • Type of pole
      2P
    • Neutral posi­tion
      Left
    Capa­city
    • Number of modules
      2
    Voltage
    • Rated oper­a­tional voltage Ue
      230 - 400 V
    • Continuous oper­ating voltage Uc according to IEC 61643-1
      350 V
    • Voltage protec­tion level Up according to IEC 61643-1
      1,90 kV
    • Voltage protec­tion level Up N-PE IEC 61643-11
      1500 V
    • Voltage protec­tion level Up L-N (PEN)
      1,9 kV
    • Nominal voltage
      240 - 415 V AC ± 10%
    Elec­tric current
    • Short-­cir­cuit current rating (Isccr)
      25 kA
    • Max. over­cur­rent protec­tion device, parallel connec­tion (fuse)
      125 A
    • Nominal discharge current In
      35 kA
    • Nominal discharge current In 8 - 20 µs L-N (PEN)
      35 kA
    • Follow current inter­rupting rating
      0,10 kA
    • Max. discharge current (Imax)
      65 kA
    • Max. discharge current (Imax) L-N (PEN)
      65 kA
    • Max. discharge current (Imax) N-PE
      65 kA
    • Residual current Ipe
      ≤ 0.5 mA
    Dimen­sions
    • Height
      99,50 mm
    • Width
      36 mm
    • Depth
      66,60 mm
    Use condi­tions
    • Oper­ating temper­ature
      -40 - 85 °C
    • Air humidity protec­tion
      5 - 95%
    • Stor­age/trans­port temper­ature
      -40 - 80 °C
    • Degree of pollu­tion according to IEC 60664 / IEC 60947-2
      2
    • Max. alti­tude
      4000 m
    Network config­ur­a­tion
    • Network type
      TN-S, TT
    • Network TN
      No
    • Network TN-C
      No
    • Network TN-C-S
      No
    • Network TN-S
      Yes
    • Network TT
      Yes
    • Network IT
      No
    • Network DC
      No
    Equip­ment
    • With remote signalling contact
      Yes
    Connec­tion
    • Cross-sec­tion of input and output with screws, for flex­ible conductors
      1,5 - 25 mm²
    • Cross-sec­tion of input and output with screws, for massive conductors
      1,5 - 35 mm²
    • Cross-sec­tion for rigid conductor, for protective conductor
      1,5 - 35 mm²
    • Cross-sec­tion for flex­ible conductor, for protective conductor
      1,5 - 25 mm²
    • Cross-sec­tion flex­ible conductor
      1.5 - 25 mm²
    • Cross-sec­tion flex­ible conductor (signal contact)
      0,1 - 1,5 mm²
    • Cross-sec­tion rigid conductor
      1.5 - 35 mm²
    • Cross-sec­tion rigid conductor (signal contact)
      0,1 - 1,5 mm²
    • Connect­or/plug type
      Screw terminal
    • Number of connec­tions
      1
    Stand­ards
    • Require­ment class IEC 61643
      T2
    Frequency
    • Frequency
      50 - 60 Hz
    Install­a­tion, mounting
    • Nominal tight­ening torque
      2,50 - 2,50 Nm
    • Suit­able for indoor usage
      Yes
    Config­ur­a­tion
    • With integ­rated protec­tion fuse
      No
    Connectivity
    • Mounting type
      DIN rail
    • Type of connec­tion
      Screw connec­tion
    Func­tions
    • Discon­nector indic­a­tion
      Optical, Remote signalling
    • Suit­able for addi­tional system config­ur­a­tion
      No
    Fuse
    • Fuse char­ac­ter­istics
      gG
    Specific iden­ti­ficaton attrib­utes for Protec­tion
    • Filter Type product
      SPD
    Safety
    • Mode of protec­tion
      L-N, N-PE
    • Protec­tion class
      Isol­a­tion class II
    Mater­ials
    • Product colour
      Light grey
    • RAL code
      7035
    • Material
      Ther­mo­plastic

    Environmental value

    We are committed to bettering our environmental performance by reducing our footprint while acting as a sustainability enabler for our customers. Learn More

    RoHS conform Yes
    REACh-SVHC free Yes

    Certifications and documents

    PEP for SPD 2P T2 TNS/TT Uc 350V In 10kA Imax 20kA remote contact
    PDF
    347,52 kB
    REACH declaration SPL265R
    PDF
    Hager RoHS report SPL265R
    PDF

    Downloads

    • Image SPL265R  | Hager

      Product Image SPL265R

    • Installation manual

      Image Installation manual zh-CN, en-GB 2020-01-01  | Hager

      Installation manual zh-CN, en-GB 2020-01-01

      PDF
      14,68 MB
    More documentation

    Discover our other products of this range

      5
    • 1
      SPL212R - SPD 2P T1+T2 TNS/TT Uc 350V Iimp 12.5kA remote contact
      SPL212R
      SPD 2P T1+T2 TNS/TT Uc 350V Iimp 12.5kA remote contact
    • 2
      SPL412R - SPD 4P T1+T2 TNS/TT Uc 350V Iimp 12.5kA remote contact
      SPL412R
      SPD 4P T1+T2 TNS/TT Uc 350V Iimp 12.5kA remote contact
    • 3
      SPL220 - SPD 2P T2 TNS/TT Uc 350V In 10kA Imax 20kA
      SPL220
      SPD 2P T2 TNS/TT Uc 350V In 10kA Imax 20kA
    • 4
      SPL240 - SPD 2P T2 TNS/TT Uc 350V In 20kA Imax 40kA
      SPL240
      SPD 2P T2 TNS/TT Uc 350V In 20kA Imax 40kA
    • 5
      SPL420 - SPD 4P T2 TNS/TT Uc 350V In 10kA Imax 20kA
      SPL420
      SPD 4P T2 TNS/TT Uc 350V In 10kA Imax 20kA

    Products and solutions

      • Product catalogue
      • Energy distribution
      • Room solutions
      • Wiring accessories

     

      • Accessibility: partially compliant

    Contact and support

      • FAQ
      • How-to-videos
      • Downloads
      • Find a distributor
      • Contact us

    Who we are

    We deliver safe and simple electrical solutions, from energy distribution to wiring accessories and room solutions for commercial and residential buildings. We want to make life on our planet safer, cleaner and more enjoyable. While being easy to work with, we remain by your side throughout the entire project, cooperating, collaborating and co-creating with you.

     

    More about us

    Fol­low us

    • Privacy
    • Cookies
    • Report a vulnerability

    © Hager Electro Private Limited