Hager The Hager h3 x160 TM FIX 1P1D 25A moulded case circuit breaker protects single-phase circuits against overloads and short circuits. Rated 25A with 25kA Icu (20kA Ics), 690V Ui and 8kV Uimp for high fault endurance. Fixed thermal‑magnetic trip, 10 ms opening, IP4X. Compact 25 mm width. Copper screw terminals 6-95 mm². Ideal for commercial and industrial panel mounting (non‑DIN).
EAN
3250613135966
Packaging
1 Piece
Technical properties
Electric current
-
Rated current25 A
-
Rated ultimate short-circuit breaking capacity Icu under 240 V AC IEC 60947-225 kA
-
Rated service breaking capacity Ics under 230 V AC according to IEC 60947-220 kA
-
Rated current 10°C according to IEC 6094729,60 A
-
Rated current 15°C according to IEC 6094729 A
-
Rated current 20°C according to IEC 6094728,50 A
-
Rated current 25°C according to IEC 6094727,90 A
-
Rated current 30°C according to IEC 6094727,40 A
-
Rated current at 35°C according to IEC 6094726,80 A
-
Rated current at 40°C according to IEC 6094726,20 A
-
Rated current 45°C according to IEC 6094725,60 A
-
Rated current 50°C according to IEC 6094725 A
-
Rated current 55°C according to IEC 6094724,30 A
-
Rated current at 60°C according to IEC 6094723,70 A
-
Rated current 65°C according to IEC 6094723 A
-
Rated current 70°C according to IEC 6094722,30 A
Architecture
-
Number of poles1
-
Neutral positionWithout neutral
Tripping
-
Response time when opening10 ms
Frequency
-
Frequency50 - 60 Hz
Voltage
-
Rated impulse withstand voltage Uimp8000 V
-
Rated insulation voltage Ui690 V
-
Rated operational voltage Ue220 - 240 V
Functions
-
Trip unitTM F/F
Power
-
Total power loss under IN4,30 W
Endurance
-
Electric endurance in number of cycles10000
-
Number of mechanical operations20000
Safety
-
Ingress Protection (IP) classIP4X
Connection
-
Cross-section flexible conductor6 - 70 mm²
-
Cross-section rigid conductor6 - 95 mm²
Installation, mounting
-
Nominal tightening torque6 - 6 Nm
-
Nominal tightening torque down terminal6 - 6 Nm
-
Nominal tightening torque top terminal6 - 6 Nm
Connectivity
-
Type of connectionScrew terminal
Settings
-
Thermal protection knob setting xIN1, 1
Cable
-
Cable materialCopper
Dimensions
-
Height130 mm
-
Width25 mm
-
Depth68 mm
Compatibility
-
Suitable for DIN RailNo
Main electrical attributes
-
Magnetic protection trip time0 - 0 ms
Environmental value
We are committed to improve our environmental performance by reducing our carbon footprint. Learn More
Certifications and documents
Downloads
-
Product image
-
Product datasheet
Hager Product data sheet HHA023Z
Moulded Case Circuit Breaker h3 x160 TM FIX 1P1D 25A 25kA CTC
PDF -
Installation manual
Installation manual International 2021-06-07
PDF8,51 MB -
Declaration of conformity
EU Declaration of Conformity
Declaration of conformity en-GB 2025-03-20
PDF430,96 kB
UKCA Declaration of Conformity
Declaration of conformity en-GB 2025-03-20
PDF435,49 kB
More documentation