    • ECP300C
    EAN
    3250612231393
    Packaging
    1 Piece
    • Energy Meters / Kilo­wat­t-Hour Meters

    3 Phase kWhmeter via CT 1A or 5A 4M S0 MID ECP300C

    Add to a list
    Add to a list

    Login to create a product list

    You need to be logged into your myHager account to create product lists

    Create an account Sign in

    3 Phase kWhmeter via CT 1A or 5A 4M S0 MID

    ECP300C

    • Accessories
    • Technical properties
    • Environmental value
    • Documentations
    • More products
    Download the data sheet

    Complete your system

    Compatible products

    • Suitable with 1 products available

    Suitable with

    • TXF121

      KNX interface for electrical energy meters

      EUR 0.00  / *

    Technical properties

    Archi­tec­ture
    • Type of pole
      3P+N
    Elec­tric current
    • Rated current
      5 A
    • Maximum meas­uring circuit current
      6 A
    Capa­city
    • Number of modules
      4
    Dimen­sions
    • Height
      90 mm
    • Width
      72 mm
    • Depth
      60 mm
    Equip­ment
    • Type of pulse gener­ator
      Elec­trical
    Compat­ib­ility
    • Suit­able for
      Purchase/supply
    Install­a­tion, mounting
    • Nominal tight­ening torque
      1 - 1 Nm
    • Mounting on
      DIN rail
    Mech­an­ical features
    • Nominal tight­ening torque digital terminal
      0,50 - 0,50 Nm
    Meas­ure­ment
    • Meas­uring system
      Meas­ure­ment trans­former
    • Type of meas­uring instru­ment
      Elec­tronic
    • Current meas­ure­ment range
      0,01 - 6,0 A
    • Meas­ure­ment range voltage Ph-N
      92 - 276 V
    • Meas­ure­ment range voltage Ph-Ph
      160 - 480 V
    • Frequency meas­uring range
      45 - 65 Hz
    Power supply
    • Number of phases for power supply
      4
    Func­tions
    • Accuracy class
      B
    • Tariff type
      T1...T2 (230 V AC)/-
    • Is calib­rated
      Yes
    Safety
    • Ingress Protec­tion (IP) class
      IP20
    Use condi­tions
    • Oper­ating temper­ature
      -25 - 55 °C
    • Stor­age/trans­port temper­ature
      -25 - 70 °C
    Power
    • Power consump­tion VA
      2 VA
    • Total power loss under IN
      0,60 W
    Frequency
    • Frequency
      50 - 50 Hz

    Environmental value

    We are committed to improve our environmental performance by reducing our carbon footprint. Learn More

    RoHS conform Yes
    REACh-SVHC free Yes

    Certifications and documents

    Hager REACH declaration ECP300C
    PDF
    Hager RoHS report ECP300C
    PDF

    Downloads

    • Product image

      Image ECP300C  | Hager Australia

      Product Image ECP300C

    • Product datasheet

      Image Hager Product data sheet ECP300C  | Hager Australia

      Hager Product data sheet ECP300C

      3 Phase kWhmeter via CT 1A or 5A 4M S0 MID

      PDF
    • Instruction manual

      Image Instruction manual International 2024-02-21  | Hager Australia

      Instruction manual International 2024-02-21

      PDF
      311,47 kB
    • Manual

      Image Installer leaflet ECP300C  | Hager Australia

      Installer leaflet ECP300C

      Manual de-DE, en-GB 2024-01-29

      PDF
      3,60 MB
    • Technical brochures

      Image Energy Meters Specifications and Technical Guide  | Hager Australia

      Energy Meters Specifications and Technical Guide

      Technical brochures en-GB 2022-01-11

      PDF
      1,31 MB
    • Brochure

      Image Energy Meters Brochure  | Hager Australia

      Energy Meters Brochure

      Track, communicate, optimise. Welcome to the smart, connected and efficient building.

      PDF
      15,44 MB
    • Declaration of conformity

      Image EU Declaration of Conformity  | Hager Australia

      EU Declaration of Conformity

      Declaration of conformity en-GB 2024-04-15

      PDF
      465,71 kB
    More documentation

    Discover more of this product range

      5
    • 1
      ECR180T - 1 Phase kWhmeter direct 3x80A 4M MODBUS
      ECR180T
      1 Phase kWhmeter direct 3x80A 4M MODBUS
    • 2
      ECR140D - 1 Phase kWhmeter direct 40A 1M MODBUS MID
      ECR140D
      1 Phase kWhmeter direct 40A 1M MODBUS MID
    • 3
      ECR180D - 1 Phase kWhmeter direct 80A 2M MODBUS MID
      ECR180D
      1 Phase kWhmeter direct 80A 2M MODBUS MID
    • 4
      ECR300C - 3 Phase kWhmeter via CT 1A or 5A 4M MODBUS MID
      ECR300C
      3 Phase kWhmeter via CT 1A or 5A 4M MODBUS MID
    • 5
      ECP140D - 1 Phase kWhmeter direct 40A 1M S0 MID
      ECP140D
      1 Phase kWhmeter direct 40A 1M S0 MID

    Products

    • Enclosures
    • DIN rail-mounted devices
    • Main Switchgear
    • Switches and Sockets
    • Motion and Presence Detectors
    • Trunking Systems

    Project Solutions

    • Product and Installations Solutions
    • Case Studies
    • Electrical Contractor Solutions
    • Architects and Specifiers Solutions
      Panelboard Builder Solutions
    • Builder and Developer Solutions

    Contact and Support

    • Safety Recalls
    • FAQs
    • How to Videos
    • Find a Wholesaler
    • Contact Us
    • Career

    Who we are

    Our international family business has been the partner of professionals in electrical engineering for over 65 years.

    Solutions for reliable energy distribution, cable management, attractive switchgear, and building automation: we are driven to deliver. Always in close cooperation with partners and customers. Our products and systems distinguish themselves in quality, simplicity in installation and use, and an attractive design.

    More about us & Working with us

     

    Follow us!

    • Terms and conditions
    • Privacy
    • Cookies
    • Hagergroup
    • Report a vulnerability

    © Ha­ger Group