Moulded Case Circuit Breaker h3+ P630 LSI 3P3D 400A 40kA FTC

HNW400JR

  • Main Switchgear

Moulded Case Circuit Breaker h3+ P630 LSI 3P3D 400A 40kA FTC HNW400JR

EAN
3250613198435
Packaging
1 Piece

You have to log in with your myHager profile to see prices and to order.

Add to a list
Add to a list

Login to create a product list

You need to be logged into your myHager account to create product lists

Create an account Sign in
  • Accessories
  • Technical properties
  • Environmental value
  • Documentations
  • More products
Download the data sheet

Complete your system

Optional accessories

  • Auxil­i­aries data cable adaptor 1 products available
  • Auxil­i­aries contact block 1 products available
  • Handle for power circuit breaker 2 products available
  • Handle with inter­lock for power breaker 1 products available
  • Motor oper­ator 2 products available
  • See more 7 other products available

Complete your system

  • Auxil­i­aries data cable adaptor
  • Auxil­i­aries contact block
  • Handle for power circuit breaker
  • Handle with inter­lock for power breaker
  • Motor oper­ator
  • Door coup­ling handle
  • Connec­tion Func­tions
  • Phase separ­a­tion func­tions
  • Terminal cover
  • HTC130H

    OAC/PTA adaptor for h3+ length 1,20 m

    0.00 €  / *
    Add to a list
    Add to a list
  • HXA028H

    Alarm contact-Low level NO-NC right side (x630/P630)

    0.00 €  / *
    Add to a list
    Add to a list
  • HXW030H

    Direct rotary handle for x630/P630

    0.00 €  / *
    Add to a list
    Add to a list
  • HXW031H

    Rotary grey handle on door x/P630

    0.00 €  / *
    Add to a list
    Add to a list
  • HXW032H

    Direct rotary handle for x630/P630, with door lock

    0.00 €  / *
    Add to a list
    Add to a list
  • HXW042H

    Motor Operator x630/P630 100-240VAC with Auto-Reset

    0.00 €  / *
    Add to a list
    Add to a list
  • HXW044H

    Motor Operator x630/P630 100-240VAC without Auto-Reset

    0.00 €  / *
    Add to a list
    Add to a list
  • HXW901H

    Handle size 2 IP55 (10x10mm)

    0.00 €  / *
    Add to a list
    Add to a list
  • HYW011H

    Spread terminal extension x630/P630 3P (up to 400A)

    0.00 €  / *
    Add to a list
    Add to a list
  • HYW019H

    Interphase barrier for x630/P630 3/4P

    0.00 €  / *
    Add to a list
    Add to a list
  • HYW021H

    Terminal cover for Straight terminal extension x630/P630 3P

    0.00 €  / *
    Add to a list
    Add to a list
  • HYW023H

    Terminal cover for Spread terminal extension x630/P630 3P

    0.00 €  / *
    Add to a list
    Add to a list
  • HYW050H

    Earth plate for Straight terminal extension P630 3P

    0.00 €  / *
    Add to a list
    Add to a list
  • HYW052H

    Earth plate for Spread terminal extension P630 3P

    0.00 €  / *
    Add to a list
    Add to a list

Technical properties

Elec­tric current
  • Rated current
    400 A
  • Rated ulti­mate short-­cir­cuit breaking capa­city Icu under 230 V AC IEC 60947-2
    70 kA
  • Rated ulti­mate short-­cir­cuit breaking capa­city Icu under 240 V AC IEC 60947-2
    70 kA
  • Rated ulti­mate short-­cir­cuit breaking capa­city Icu under 400 V AC IEC 60947-2
    40 kA
  • Rated ulti­mate short-­cir­cuit breaking capa­city Icu under 415 V AC IEC 60947-2
    40 kA
  • Breaking capa­city on 1-pole for AC 230 V IEC 60947-2
    10 kA
  • Breaking capa­city on 1-pole for AC 400 V IEC 60947-2
    10 kA
  • Rated ulti­mate short-­cir­cuit breaking capa­city Icu under 690 V AC IEC 60947-2
    7 kA
  • Rated service breaking capa­city Ics under 220 V AC according to IEC 60947-2
    70 kA
  • Rated service breaking capa­city Ics under 230 V AC according to IEC 60947-2
    70 kA
  • Rated service breaking capa­city Ics under 240 V AC according to IEC 60947-2
    70 kA
  • Rated service breaking capa­city Ics under 380 V AC according to IEC 60947-2
    40 kA
  • Rated service breaking capa­city Ics under 400 V AC according to IEC 60947-2
    40 kA
  • Rated service breaking capa­city Ics under 415 V AC according to IEC 60947-2
    40 kA
  • Rated service breaking capa­city Ics under 690 V AC according to IEC 60947-2
    7 kA
  • Rated current 10°C according to IEC 60947
    400 A
  • Rated current 15°C according to IEC 60947
    400 A
  • Rated current 20°C according to IEC 60947
    400 A
  • Rated current 25°C according to IEC 60947
    400 A
  • Rated current 30°C according to IEC 60947
    400 A
  • Rated current at 35°C according to IEC 60947
    400 A
  • Rated current at 40°C according to IEC 60947
    400 A
  • Rated current 45°C according to IEC 60947
    400 A
  • Rated current 50°C according to IEC 60947
    400 A
  • Rated current 55°C according to IEC 60947
    400 A
  • Rated current at 60°C according to IEC 60947
    400 A
  • Rated current 70°C according to IEC 60947
    400 A
  • Rated current 65°C according to IEC 60947
    400 A
Archi­tec­ture
  • Number of poles
    3
  • Control/­op­er­a­tion element
    Toggle
  • Device construc­tion type
    Fixed built-in
  • Neutral posi­tion
    Without neutral
Trip­ping
  • Response time when opening
    10 ms
Settings
  • Ir1 current dial setting
    160 A, 180 A, 200 A, 225 A, 250 A, 300 A, 350 A, 370 A, 400 A
  • Adjust­ment range short-term delayed short-­cir­cuit release
    218,4 - 4000,0 A
Frequency
  • Frequency
    50 - 60 Hz
Install­a­tion, mounting
  • Nominal tight­ening torque
    18 - 18 Nm
  • Mount­ing-/­Con­nec­tion Posi­tion
    Front
Voltage
  • Rated impulse with­stand voltage Uimp
    8000 V
  • Rated insu­la­tion voltage Ui
    800 V
  • Rated oper­a­tional voltage Ue
    220 - 690 V
Func­tions
  • Trip unit
    LSI
Power
  • Total power loss under IN
    57,8 W
  • Power loss per pole at In
    19,3 W
Equip­ment
  • Number of auxil­iary contacts as change-over contact
    0
  • Number of auxil­iary contacts as normally closed contact
    0
  • Number of auxil­iary contacts as normally open contact
    0
Safety
  • Ingress Protec­tion (IP) class
    IP4X
Use condi­tions
  • Oper­ating temper­ature
    -25 - 70 °C
  • Degree of pollu­tion according to IEC 60664 / IEC 60947-2
    3
Connec­tion
  • Connect­or/plug type
    Terminal
Cable
  • Cable material
    Copper
Dimen­sions
  • Height
    260 mm
  • Width
    140 mm
  • Depth
    150 mm
Controls and indic­ators
  • Motor drive integ­rated
    No
Compat­ib­ility
  • Suit­able for DIN Rail
    No
  • Compat­ible with RDC AOB
    Yes
  • Suit­able for distri­bu­tion board
    Yes
Power supply
  • Posi­tion power supply
    Bidirec­tional
Elec­trical protec­tion
  • Long-­time over­load protec­tion (ltd): delay (tr)
    0.5 s, 1.5 s, 2.5 s, 5 s, 7.5 s, 9 s, 10 s, 12 s, 14 s, 16 s
  • Short-­time protec­tion (std): current (Isd)
    1.5, 2, 3, 4, 5, 6, 7, 8, 10
  • Short-­time protec­tion (std): delay (tsd)
    50 ms, 100 ms, 200 ms, 300 ms, 400 ms
  • Instant­an­eous protec­tion (li): dial setting coef­fi­cient
    3, 4, 5, 6, 7, 8, 10, 11, 12

Environmental value

We are committed to improve our environmental performance by reducing our carbon footprint. Learn More

RoHS conform Yes

Certifications and documents

PEP document International 2024-03-05
PDF
426,06 kB
REACH declaration HNW400JR (english)
PDF
103,34 kB
RoHS declaration HNW400JR (english)
PDF
103,84 kB

Downloads

  • Product image

    Image HNW400JR  | Hager New Zealand

    Product Image HNW400JR

  • ProductNotice

    Image Instruction manual International 2025-01-21  | Hager New Zealand

    Instruction manual International 2025-01-21

    PDF
    10,29 MB
  • ProductBimStep

    Image CAD file for MCCB 630A 3P  | Hager New Zealand

    CAD file for MCCB 630A 3P

    STEP files International 2023-11-24

    STP
    921,20 kB
  • ProductECDeclaration

    Image EU Declaration of Conformity  | Hager New Zealand

    EU Declaration of Conformity

    PDF
    588,41 kB
    Image EU declaration of conformity  | Hager New Zealand

    EU declaration of conformity

    PDF
    569,34 kB
More documentation

Discover more of this product range

    5
  • 1
    HED630H - Moulded Case Circuit Breaker h630 3P 70kA 630A LSI
    HED630H
    Moulded Case Circuit Breaker h630 3P 70kA 630A LSI
  • 2
    HHJ400DR - Moulded Case Circuit Breaker h3 x630 TM ADJ 3P3D 400A 25kA FTC
    HHJ400DR
    Moulded Case Circuit Breaker h3 x630 TM ADJ 3P3D 400A 25kA FTC
  • 3
    HHS025DR - Moulded Case Circuit Breaker h3+ P160 TM ADJ 3P3D 25A 25kA FTC
    HHS025DR
    Moulded Case Circuit Breaker h3+ P160 TM ADJ 3P3D 25A 25kA FTC
  • 4
    HHS040DR - Moulded Case Circuit Breaker h3+ P160 TM ADJ 3P3D 40A 25kA FTC
    HHS040DR
    Moulded Case Circuit Breaker h3+ P160 TM ADJ 3P3D 40A 25kA FTC
  • 5
    HHS040JR - Moulded Case Circuit Breaker h3+ P160 LSI 3P3D 40A 25kA FTC
    HHS040JR
    Moulded Case Circuit Breaker h3+ P160 LSI 3P3D 40A 25kA FTC

Products

  • Enclosures
  • DIN rail-mounted devices
  • Main Switchgear
  • Switches and Sockets
  • Motion and Presence Detectors
  • Trunking Systems

Project Solutions

  • Product and Installations Solutions
  • Case Studies
  • Electrical Contractor Solutions
  • Architects and Specifiers Solutions
    Panelboard Builder Solutions
  • Builder and Developer Solutions

Contact and Support

  • Safety Recalls
  • FAQs
  • How to Videos
  • Contact Us

Who we are

Our international family business has been the partner of professionals in electrical engineering for over 65 years.

Solutions for reliable energy distribution, cable management, attractive switchgear, and building automation: we are driven to deliver. Always in close cooperation with partners and customers. Our products and systems distinguish themselves in quality, simplicity in installation and use, and an attractive design.

More about us & Working with us

Follow us!

  • Terms and conditions
  • Privacy
  • Cookies
  • Hagergroup
  • Report a vulnerability

© 2021 Ha­ger Group