MCCB h3+ P250 LSI 3x250A 40kA • HNT250JR | Hager
The store will not work correctly in the case when cookies are disabled.
New-Zealand
  • Contact
Image Logo  | Hager New Zealand
Menu
  • Products
  • Solutions for your project
  • Inspiration and Knowledge
  • Support
  • About Us
Account
  • Catalog
  • Main Switchgear
  • Moulded Case Circuit Breakers (MCCBs)
  • MCCBs
  • HNT250JR

Moulded Case Circuit Breaker h3+ P250 LSI 3P3D 250A 40kA FTC

HNT250JR

  • Main Switchgear

Moulded Case Circuit Breaker h3+ P250 LSI 3P3D 250A 40kA FTC HNT250JR

EAN
3250613176822
Packaging
1 Piece

You have to log in with your myHager profile to see prices and to order.

Add to a list
Add to a list

Login to create a product list

You need to be logged into your myHager account to create product lists

Create an account Sign in
  • Accessories
  • Technical properties
  • Environmental value
  • Documentations
  • More products
Download the data sheet

Complete your system

Optional accessories

  • Auxil­i­aries data cable adaptor 1 products available
  • Auxil­i­aries contact block 1 products available
  • Handle for power circuit breaker 1 products available
  • Door coup­ling handle 1 products available
  • Handle with inter­lock for power breaker 1 products available
  • See more 7 other products available

Complete your system

  • Auxil­i­aries data cable adaptor
  • Auxil­i­aries contact block
  • Handle for power circuit breaker
  • Door coup­ling handle
  • Handle with inter­lock for power breaker
  • Motor oper­ator
  • Phase separ­a­tion func­tions
  • Terminal cover
  • HTC130H

    OAC/PTA adaptor for h3+ length 1,20 m

    0.00 €  / *
    Add to a list
    Add to a list
  • HXA028H

    Alarm contact-Low level NO-NC right side (x630/P630)

    0.00 €  / *
    Add to a list
    Add to a list
  • HXT030H

    Direct rotary handle for P250

    0.00 €  / *
    Add to a list
    Add to a list
  • HXT031H

    Rotary handle on door P250

    0.00 €  / *
    Add to a list
    Add to a list
  • HXT032H

    Direct rotary handle P250 with interlocking

    0.00 €  / *
    Add to a list
    Add to a list
  • HXT042H

    Motor Operator P250 230-240VAC with Auto-Reset

    0.00 €  / *
    Add to a list
    Add to a list
  • HXT044H

    Motor Operator P250 230-240VAC without Auto-Reset

    0.00 €  / *
    Add to a list
    Add to a list
  • HYT019H

    Interphase barrier for P250 3/4P

    0.00 €  / *
    Add to a list
    Add to a list
  • HYT021H

    Terminal cover for Straight terminal extension P250 3P

    0.00 €  / *
    Add to a list
    Add to a list
  • HYT023H

    Terminal cover for Spread terminal extension P250 3P

    0.00 €  / *
    Add to a list
    Add to a list
  • HYT050H

    Earth plate for Straight terminal extension P250 3P

    0.00 €  / *
    Add to a list
    Add to a list
  • HYT052H

    Earth plate for Spread terminal extension P250 3P

    0.00 €  / *
    Add to a list
    Add to a list

Technical properties

Elec­tric current
  • Rated current
    250 A
  • Rated ulti­mate short-­cir­cuit breaking capa­city Icu under 230 V AC IEC 60947-2
    50 kA
  • Rated ulti­mate short-­cir­cuit breaking capa­city Icu under 240 V AC IEC 60947-2
    50 kA
  • Rated ulti­mate short-­cir­cuit breaking capa­city Icu under 400 V AC IEC 60947-2
    40 kA
  • Rated ulti­mate short-­cir­cuit breaking capa­city Icu under 415 V AC IEC 60947-2
    40 kA
  • Breaking capa­city on 1-pole for AC 230 V IEC 60947-2
    2,50 kA
  • Breaking capa­city on 1-pole for AC 400 V IEC 60947-2
    2,50 kA
  • Rated ulti­mate short-­cir­cuit breaking capa­city Icu under 690 V AC IEC 60947-2
    6 kA
  • Rated service breaking capa­city Ics under 220 V AC according to IEC 60947-2
    50 kA
  • Rated service breaking capa­city Ics under 230 V AC according to IEC 60947-2
    50 kA
  • Rated service breaking capa­city Ics under 240 V AC according to IEC 60947-2
    50 kA
  • Rated service breaking capa­city Ics under 380 V AC according to IEC 60947-2
    40 kA
  • Rated service breaking capa­city Ics under 400 V AC according to IEC 60947-2
    40 kA
  • Rated service breaking capa­city Ics under 415 V AC according to IEC 60947-2
    40 kA
  • Rated service breaking capa­city Ics under 690 V AC according to IEC 60947-2
    6 kA
  • Rated current 10°C according to IEC 60947
    250 A
  • Rated current 15°C according to IEC 60947
    250 A
  • Rated current 20°C according to IEC 60947
    250 A
  • Rated current 25°C according to IEC 60947
    250 A
  • Rated current 30°C according to IEC 60947
    250 A
  • Rated current at 35°C according to IEC 60947
    250 A
  • Rated current at 40°C according to IEC 60947
    250 A
  • Rated current 45°C according to IEC 60947
    250 A
  • Rated current 50°C according to IEC 60947
    250 A
  • Rated current 55°C according to IEC 60947
    250 A
  • Rated current at 60°C according to IEC 60947
    240 A
  • Rated current 70°C according to IEC 60947
    200 A
  • Rated current 65°C according to IEC 60947
    220 A
Archi­tec­ture
  • Number of poles
    3
  • Control/­op­er­a­tion element
    Toggle
  • Device construc­tion type
    Fixed built-in
  • Neutral posi­tion
    Without neutral
Settings
  • Ir1 current dial setting
    90 A, 100 A, 110 A, 125 A, 140 A, 160 A, 180 A, 200 A, 225 A, 250 A
  • Adjust­ment range short-term delayed short-­cir­cuit release
    122,9 - 2500,0 A
Frequency
  • Frequency
    50 - 60 Hz
Install­a­tion, mounting
  • Nominal tight­ening torque
    12 - 12 Nm
  • Mount­ing-/­Con­nec­tion Posi­tion
    Front
Voltage
  • Rated impulse with­stand voltage Uimp
    8000 V
  • Rated insu­la­tion voltage Ui
    800 V
  • Rated oper­a­tional voltage Ue
    220 - 690 V
Func­tions
  • Trip unit
    LSI
Power
  • Total power loss under IN
    45 W
  • Power loss per pole at In
    15 W
Endur­ance
  • Elec­tric endur­ance in number of cycles
    10000
  • Number of mech­an­ical oper­a­tions
    40000
Equip­ment
  • Number of auxil­iary contacts as change-over contact
    0
  • Number of auxil­iary contacts as normally closed contact
    0
  • Number of auxil­iary contacts as normally open contact
    0
Safety
  • Ingress Protec­tion (IP) class
    IP4X
Use condi­tions
  • Oper­ating temper­ature
    -25 - 70 °C
  • Degree of pollu­tion according to IEC 60664 / IEC 60947-2
    3
Connec­tion
  • Cross-sec­tion flex­ible conductor
    35 - 150 mm²
  • Cross-sec­tion rigid conductor
    35 - 185 mm²
  • Connect­or/plug type
    Terminal
Cover, door
  • Inter­lock­able
    Yes
Cable
  • Cable material
    Copper, Aluminium
Dimen­sions
  • Height
    165 mm
  • Width
    105 mm
  • Depth
    97 mm
Controls and indic­ators
  • Motor drive integ­rated
    No
Compat­ib­ility
  • Suit­able for DIN Rail
    No
  • Compat­ible with RDC AOB
    No
  • Suit­able for distri­bu­tion board
    Yes
Power supply
  • Posi­tion power supply
    Bidirec­tional
Elec­trical protec­tion
  • Long-­time over­load protec­tion (ltd): delay (tr)
    0.5 s, 1.5 s, 2.5 s, 5 s, 7.5 s, 9 s, 10 s, 12 s, 14 s, 16 s
  • Short-­time protec­tion (std): current (Isd)
    1.5, 2, 3, 4, 5, 6, 7, 8, 10
  • Short-­time protec­tion (std): delay (tsd)
    50 ms, 100 ms, 200 ms, 300 ms, 400 ms
  • Instant­an­eous protec­tion (li): dial setting coef­fi­cient
    3, 4, 5, 6, 7, 8, 9, 10, 11

Environmental value

We are committed to improve our environmental performance by reducing our carbon footprint. Learn More

RoHS conform Yes

Certifications and documents

REACH declaration HNT250JR (english)
PDF
103,34 kB
RoHS declaration HNT250JR (english)
PDF
103,84 kB

Downloads

  • Product image

    Image HNT250JR  | Hager New Zealand

    Product Image HNT250JR

  • ProductBimStep

    Image CAD file for MCCB 250A 3P  | Hager New Zealand

    CAD file for MCCB 250A 3P

    STEP files International 2023-11-24

    STP
    640,83 kB
  • ProductECDeclaration

    Image Declaration  | Hager New Zealand

    Declaration

    Declaration of conformity International 2022-04-25

    PDF
    349,41 kB
    Image Declaration  | Hager New Zealand

    Declaration

    Declaration of conformity International 2022-04-25

    PDF
    461,97 kB
More documentation

Discover more of this product range

    5
  • 1
    HED630H - Moulded Case Circuit Breaker h630 3P 70kA 630A LSI
    HED630H
    Moulded Case Circuit Breaker h630 3P 70kA 630A LSI
  • 2
    HHJ400DR - Moulded Case Circuit Breaker h3 x630 TM ADJ 3P3D 400A 25kA FTC
    HHJ400DR
    Moulded Case Circuit Breaker h3 x630 TM ADJ 3P3D 400A 25kA FTC
  • 3
    HHS025DR - Moulded Case Circuit Breaker h3+ P160 TM ADJ 3P3D 25A 25kA FTC
    HHS025DR
    Moulded Case Circuit Breaker h3+ P160 TM ADJ 3P3D 25A 25kA FTC
  • 4
    HHS040DR - Moulded Case Circuit Breaker h3+ P160 TM ADJ 3P3D 40A 25kA FTC
    HHS040DR
    Moulded Case Circuit Breaker h3+ P160 TM ADJ 3P3D 40A 25kA FTC
  • 5
    HHS040JR - Moulded Case Circuit Breaker h3+ P160 LSI 3P3D 40A 25kA FTC
    HHS040JR
    Moulded Case Circuit Breaker h3+ P160 LSI 3P3D 40A 25kA FTC

Products

  • Enclosures
  • DIN rail-mounted devices
  • Main Switchgear
  • Switches and Sockets
  • Motion and Presence Detectors
  • Trunking Systems

Project Solutions

  • Product and Installations Solutions
  • Case Studies
  • Electrical Contractor Solutions
  • Architects and Specifiers Solutions
    Panelboard Builder Solutions
  • Builder and Developer Solutions

Contact and Support

  • Safety Recalls
  • FAQs
  • How to Videos
  • Contact Us

Who we are

Our international family business has been the partner of professionals in electrical engineering for over 65 years.

Solutions for reliable energy distribution, cable management, attractive switchgear, and building automation: we are driven to deliver. Always in close cooperation with partners and customers. Our products and systems distinguish themselves in quality, simplicity in installation and use, and an attractive design.

More about us & Working with us

Follow us!

  • Terms and conditions
  • Privacy
  • Cookies
  • Hagergroup
  • Report a vulnerability

© 2021 Ha­ger Group