Moulded Case Circuit Breaker h3 x160 TM FIX 1P1D 50A 25kA CTC HHA048Z
EAN
3250613135997
Packaging
1 Piece
Login to create a product list
You need to be logged into your myHager account to create product lists
Technical properties
Architecture
-
Neutral positionwithout neutral
-
Number of protected poles1
-
Number of poles1 P
-
Type of pole1P1D
Functions
-
Trip UnitTM F/F
-
Integrated earth fault protectionNo
-
Concurrently switching N-neutralNo
Controls and indicators
-
Motor drive integratedNo
Main electrical features
-
Rated operational voltage Ue220 / 240 V
-
Frequency50/60 Hz
Voltage
-
Rated insulation voltage690 V
-
Rated impulse withstand voltage8 kV
-
With under voltage releaseNo
Electric current
-
Rated current50 A
-
Thermal protection nob setting xIN1
-
Rating current 10°C according to IEC 6094761 A
-
Rating current 15°C according to IEC 6094759.8 A
-
Rating current 20°C according to IEC 6094758.5 A
-
Rating current 25°C according to IEC 6094757.1 A
-
Rating current 30°C according to IEC 6094755.8 A
-
Rating current 35°C according to IEC 6094754.4 A
-
Rating current 40°C according to IEC 6094752.9 A
-
Rating current 45°C according to IEC 6094751.5 A
-
Rating current 50°C according to IEC 6094750 A
-
Rating current 55°C according to IEC 6094748.4 A
-
Rating current 60°C according to IEC 6094746.8 A
-
Rating current 65°C according to IEC 6094745.1 A
-
Rating current 70°C according to IEC 6094743.4 A
-
Breaking capacity on 1 pole for IT 230V NF 60947-225 kA
-
Rated ultimate short-circuit breaking capacity Icu under 230V AC IEC 60947-225 kA
-
Rated ultimate short-circuit breaking capacity Icu under 240V AC IEC 60947-225 kA
-
Range of the thermal adjustment50 A
-
Rated ultimate short-circuit breaking capacity Icu under 220V AC IEC 60947-225 kA
Dimensions
-
Depth of installed product68 mm
-
Height of installed product130 mm
-
Width of installed product25 mm
Frequency
-
Frequency50 to 60 Hz
Power
-
Total power loss under IN5 W
-
Power loss per pole at In5 W
Endurance
-
Electric endurance in number of cycles1000
-
Number of mechanical operations4000
Connection
-
Type of connectionwith screw
Settings
-
Range of the magnetic adjustment600 A
Equipment
-
Number of auxiliary contacts as normally closed contact0
-
Number of auxiliary contacts as normally open contact0
-
Number of auxiliary contacts as change-over contact0
-
Can be accessorizedYes
Standards
-
Standard textIEC 60947-2
Safety
-
REACH conformYes
-
RoHS conformYes
-
Halogen freeNo
Use conditions
-
Degree of pollution according to IEC 60664 / IEC 60947-23
-
Altitude2000 m
temperatur
-
Temperature of calibration50 °C
Downloads
-
Product image
-
ProductNotice
Instruction manuals for HHA048Z
PDF8 MB -
ProductECDeclaration
Declaration
PDF215 KBDeclaration
PDF276 KB -
ProductROHS
REACH-declaration 2023-10-20 (english)
PDF32 KBRoHS-declaration 2023-10-20 (english)
PDF33 KB
More documentation