Load break switch with visible breaking 4P 125A HA406

EAN
3250613114060
Packaging
1 Piece

You have to log in with your myHager profile to see prices and to order.

Add to a list
Add to a list

Login to create a product list

You need to be logged into your myHager account to create product lists

Create an account Sign in

Load break switch with visible breaking 4P 125A

HA406

  • Accessories
  • Technical properties
  • Environmental value
  • Documentations
  • More products
Download the data sheet

Complete your system

Optional accessories

  • See more (1)
    • Auxil­iary contact block 1 products available

    Complete your system

    • Auxil­iary contact block
    • HZ022

      Auxiliary contact 1C+1O ha100/160

      0.00 €  / *

    Technical properties

    Elec­tric current
    • Rated current
      125 A
    • Accept­able current rating AC21
      125 A
    • Accept­able current rating AC21 category A
      125 A
    • Accept­able current rating AC21 category B
      125 A
    • Accept­able current rating AC22 category A
      125 A
    • Accept­able current rating AC22 category B
      125 A
    • Accept­able current rating AC23 category A
      63 A
    • Accept­able current rating AC23 category B
      63 A
    • Rated short-­time with­stand current Icw 1s IEC 60947
      2,50 kA
    • Rated short-­time with­stand current Icw IEC 60947
      2,50 kA
    Connec­tion
    • Cross-sec­tion rigid conductor
      50 mm² max.
    • Cross-sec­tion flex­ible conductor
      50 mm²
    Voltage
    • Rated insu­la­tion voltage Ui
      800 V
    • Rated impulse with­stand voltage Uimp
      8000 V
    • Rated oper­a­tional voltage Ue
      380 - 415 V
    Power
    • Power loss per pole at In
      5,70 W
    • Total power loss under IN
      17,10 W
    • Rated oper­a­tional power under 400 V AC AC1
      82000 W
    • Rated oper­a­tional power under 400 V AC AC23
      28000 W
    Equip­ment
    • Motor drive optional
      No
    • Number of auxil­iary contacts as change-over contact
      0
    • Number of auxil­iary contacts as normally closed contact
      0
    • Number of auxil­iary contacts as normally open contact
      0
    Use condi­tions
    • Oper­ating temper­ature
      -20 - 70 °C
    Cover, door
    • Inter­lock­able
      Yes
    Safety
    • Ingress Protec­tion (IP) class
      IP20
    Archi­tec­ture
    • Type of pole
      4P
    • Number of poles
      4
    • Control/­op­er­a­tion element
      Short rotary handle
    Frequency
    • Frequency
      50 - 50 Hz
    Func­tions
    • Is reversing switch
      No
    • Version as emer­gency stop install­a­tion
      No
    • Version as main switch
      Yes
    • Version as main­ten­ance/ser­vice switch
      Yes
    • Version as safety switch
      Yes
    • Version as switch discon­nector compact
      Yes
    Capa­city
    • Number of modules
      6
    Install­a­tion, mounting
    • Nominal tight­ening torque
      6 - 6,6 Nm
    Connectivity
    • Type of connec­tion
      Screw terminal
    Dimen­sions
    • Height
      86,5 mm
    • Width
      108 mm
    • Depth
      90 mm

    Environmental value

    We are committed to improve our environmental performance by reducing our carbon footprint. Learn More

    RoHS conform Yes
    REACH conform Yes

    Certifications and documents

    Hager REACH declaration HA406
    PDF
    Hager RoHS report HA406
    PDF
    REACH declaration HA406 (english)
    PDF
    103,10 kB
    RoHS declaration HA406 (english)
    PDF
    103,59 kB

    Downloads

    • Product image

      Image HA406  | Hager New Zealand

      Product Image HA406

    • Declaration of conformity

      Image Declaration  | Hager New Zealand

      Declaration

      Declaration of conformity International 2021-05-17

      PDF
      200,64 kB
      Image Declaration  | Hager New Zealand

      Declaration

      Declaration of conformity International 2022-04-13

      PDF
      777,14 kB
    More documentation

    Discover more of this product range

      5
    • 1
      HA304 - Load break switch 3P 80A
      HA304
      Load break switch 3P 80A
    • 2
      HA305 - Load break switch 3P 100A
      HA305
      Load break switch 3P 100A
    • 3
      HA306 - Load break switch 3P 125A
      HA306
      Load break switch 3P 125A
    • 4
      HA307 - Load break switch 3P 160A
      HA307
      Load break switch 3P 160A
    • 5
      HA308 - Load break switch 3P 200A
      HA308
      Load break switch 3P 200A

    Products

    • Enclosures
    • DIN rail-mounted devices
    • Main Switchgear
    • Switches and Sockets
    • Motion and Presence Detectors
    • Trunking Systems

    Project Solutions

    • Product and Installations Solutions
    • Case Studies
    • Electrical Contractor Solutions
    • Architects and Specifiers Solutions
      Panelboard Builder Solutions
    • Builder and Developer Solutions

    Contact and Support

    • Safety Recalls
    • FAQs
    • How to Videos
    • Contact Us

    Who we are

    Our international family business has been the partner of professionals in electrical engineering for over 65 years.

    Solutions for reliable energy distribution, cable management, attractive switchgear, and building automation: we are driven to deliver. Always in close cooperation with partners and customers. Our products and systems distinguish themselves in quality, simplicity in installation and use, and an attractive design.

    More about us & Working with us

    Follow us!

    • Terms and conditions
    • Privacy
    • Cookies
    • Hagergroup
    • Report a vulnerability

    © 2021 Ha­ger Group