Concurrently switching N-neutralYes
Rating current -25°C38.3 A
Max operating voltage253 V
Rated impulse withstand voltage4 kV
Rating current 20°C33.24 A
Rating current 10°C34.43 A
Rating current 15°C33.84 A
CurveB
Altitude2000 m
Bottom removability for modular devicesYes
Can be accessorizedYes
Class of energy limitation I²t3
Correction factor of rating current for 2 devices placed side-by-side1
Correction factor of rating current for 3 devices placed side-by-side0.95
Correction factor of rating current for 4 and 5 devices placed side-by-side0.9
Correction factor of rating current for 6 devices placed side-by-side0.85
Tightening torque2Nm
Degree of pollution according to IEC 60664 / IEC 60947-22
Rating current -15°C37.24 A
Frequency (range for ETIM)50 Hz
Overvoltage category according to IEC 60947-13
Number of protected poles1
Device familyARC
Accept terminal coverNo
Height of installed product85 mm
Rated short circuit breaking capacity Icn AC according IEC60898-16 kA
Rated short circuit breaking capacity Icn under 230V AC according IEC60898-16 kA
Rated service breaking capacity Ics AC according IEC 60898-16 kA
Rated current32 A
Rating current 0°C35.58 A
Rating current -10°C36.69 A
Rated operational voltage Ue230 V
Rated insulation voltage500 V
With Contact position indicatorYes
Type of supply voltageAC
Neutral positionright
Length of conductors used for the heating test (m) according to product standard1 m
Quantity of half modules of 17,7mm4
Number of modules2
Number of poles2 P
Electric endurance in number of cycles2000
Number of mechanical operations4000
360° product mounting positionYes
CE marking on labelAI2_B5_CE_01.JPG
Depth of installed product70 mm
Power loss per pole at In5.61 W
Type of pole1P+N
Total power loss under IN8.31 W
Quick connectno
Conductor cross-section used for heating test(mm²) according to product standard6 mm²
Connection cross-section at output with screw, for flexible conductor1 / 16 mm²
Width of installed product35.5 mm
Temperature of calibration30 °C
Connection cross-section at output with screw, for massive conductor1.5 / 25 mm²
Rating current 50°C30.03 A
Rating current 25°C32.63 A
Rating current 30°C32 A
Rating current 35°C31.52 A
Rating current 40°C31.03 A
Rating current 45°C30.54 A
Rating current -5°C36.14 A
Rating current 5°C35.01 A
Downstream cage clamp delivery statusopened
Rating current 55°C29.52 A
Rating current 60°C29 A
Protection index IPIP20
Magnetic regulating currrent at 40° C3 / 5 In
min/maxi threshold value of the AC thermal operation1.13 / 1.45 In
SealableYes
Upstream cage clamp delivery statusopened
Connection cross-section of the access with screws, with flexible conductor1 / 16 mm²
Connection cross-section for rigid conductor, upstream terminals with screws1.5 / 25 mm²
Search wordsAFDD; Arc fault device; arc fault detection device; arc fault protection; arcing faults; electric arcs; series arcs; parallel arcs; arcing; arc faults; afd unit; electric fire protective device; BS EN 62606
Temperature-rise limits for terminals according to the product standard60 K
Temperature-rise measured on terminals at In41.9 K
Compatible with DIN rail mountingYes
Storage temperature-40/70 °C
Rating current -20°C37.77 A
Nominal tightening torque top terminal2 Nm
European directive WEEEconcerned
Standard textEN 62606 ; IEC 60898-1
Temp.-rise limits for access. parts (not touched) according to product standard60 K
Type of accessoryAFDD
Top removability for modular devicesNo
Type of Bottom Connection for modular devicesBIconnect
Type of bottom rail clip for modular devicesplastic
Bottom connection alignement for modular devicesAligned terminal
Type of top connection for modular deviceswith screw
Top connection alignement for modular devicesAligned terminal
Type of conductors used for the heating test according to the product standardrig Cu
Temp.rise limits for access. parts (to be touched) according to product standard40 K
Nominal tightening torque bottom terminal2 Nm
Temp.-rise limits for access. parts (toggle) according to product standard25 K
Temperature-rise measured on accessible parts at In (intended to be touched)30.1 K
Suitable for flush-mountingYes
Ambient air temperature during heating test according to the product standard23.5 °C
Max. admissible temperature on accessible parts (intended to be touched)70.1 °C
Temperature-rise measured on access. parts at In (not touched normal operation)53.7 K
Max. admissible temperature on access. parts (not touched for normal operation)93.7 °C
Max. admissible temperature on terminals81.9 °C
Operating temperature-25/60 °C
Max. admissible temperature on accessible parts (manual operating means)52.4 °C
Temperature-rise measured on accessible parts at In (manual operating means)12.4 K
UnitPCE
Sales status3E
EAN3250611311959
See more features
Documentations
Product environmental profile for ARC932U 397 kbpdfDownload
Residential Distribution Catalogue 6109 kbpdfDownload
More documentation

Share your latest install with the #HagerGang

Join the gang

Specifying Hager

We offer a range of product solutions for any project.
Find out how we can provide you with the ideal electrical solution for your next project.

Explore solutions

Catalogues & brochures

All product documentation and datasheets just one click away!

Explore
*Data is subject to errors and technical modifications. Prices are trade price, exclusive of VAT.